"नये भारत का नया Tender Portal"
Request a call back

Latest Tenders for water proofing paint

Total 199 tenders found
#TBR: 35558799 Closed

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (0 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .

22.20 Lacs
View Tender
#TBR: 35558958 Closed

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (0 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .

9.80 Lacs
View Tender
#TBR: 35559003 Closed

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (0 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm) Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm)

25.85 Lacs
View Tender
#TBR: 35490960 Closed

Security Services

  • Assam
  • Due On: 09 Oct, 2025 (0 Days Left)

Gem Bids For Tube Light Slash Led Tube Light Fitting 20 W Bracket Openmake Colon Philips Tube Light 10w 2 Feet Bracket Openmake Colon Philips Led Tube Light 15w 2 Feet Bracketopen Make Colon Philips 1 Sq Mm Single Core Multistandred Copper Wire Bracket Open Make Colon Finolex 1point 5 Sqmm Single Core Multi Standred Copper Wirebracket Open Make Colon Finolex 2 Sq Mm Single Coremulti Standred Copper Wire Bracket Open Make Colon Finolex 2 Point 5 Sqmm Single Core Multi Standred Copper Wirebracket Open Make Colon Finolex Cfl 15w Bracket Openmake Colon Philips Flexible Wire 1 Sq Mm Bracket Openmake Colon Finolex 3 Pin Plug Top 5 Amp Bracket Openmakecolon Philips 3 Pin Plug Top 15 Amp Bracket Openmake Colon Philips Electric Extension Board Bracket Openmake Colon Philips Plug Female Bracket Open Make Colonphilips Plug 5 Amp 2 Pin Bracket Open Make Colon Philips Switch Socket Board 5 Amp Bracket Open Make Colon Philips Switch Socket Board15 Amp Bracket Open Make Colonphilips Switch Socket Combination 5 Slash 15 Amp Bracketopen Make Colon Philips Switch Socket Combination 15amp Bracket Open Make Colon Philips Switch Socketcombination 5 Slash 6amp Bracket Open Make Colon Philips Mcb 10 Amp Bracket Open Make Colon Havells Mcb 16amp Bracket Open Make Colon Havells Mcb 20 Ampbracket Open Make Colon Havells Mcb 32 Amp Bracketopen Make Colon Havells Mcb Dp Isolater 32 Amp Bracketopen Make Colon Havells Mcb Dp Isolator 63 Amp Bracketopen Make Colon Havells Bed Switch Bracket Open Makecolon Philips Switch 15 Amp Bracket Open Make Colonphilips Insulation Tape As Approved Sample Socket 5 Ampbracket Open Make Colon Philips Socket 15 Amp Bracketopen Make Colon Philips Pedestal Fan Bracket Open Makecolon Crompton Exhaust Fan 250mm Bracket Open Make Bid Number Gem2025b6738505 Dated 29-09-2025 Bid Document1 106 0 0 Colon Bajaj, Exhaust Fan 300 X 300mm Bracket Open Pvcmake Colon Bajaj, Exhaust Fan 450 X 450mm Bracket Openpvc Make Colon Bajaj, Ceiling Fan Bracket Open Make Coloncrompton Slash Havells, Piano Switch 5 Slash 6 Ampbracket Open Make Colon Philips, Bulb Holder Bracket Openmake Colon Philips, Angle Holder Bracket Open Make Colonphilips, Pendent Holder Bracket Open Make Colon Philips, Led Bulb 15 Watt Bracket Open Make Colon Philips, Ledbulb 12 W Bracket Open Make Colon Philips, Led Bulb 9 Wbrackey Open Make Colon Philips, Led Bulb 7 W Bracketopen Mak Colon Philips, Security Light 30w Bracket Openmake Colon Philips, Cassing Caping 2 Mtr Long Bracketopen Make Colon Finolex, Modular Switch 5 Amp Bracketopen Make Colon Philips, Modular Socket 15 Amp Bracketopen Make Colon Philips, Modular Socket 5 Amp Bracketopen Make Colon Philips, Modular Switch Piano 6 Ampbracket Open Make Colon Philips, Switch Board 7 Inch X 4inch Bracket Open Make Colon Philips, Switch Board 8 Inch X4 Inch Bracket Open Make Colon Schneider, Switch Board 6inch X 3 Inch Bracket Open Make Colon Schneider, Wallmounted Fan Bracket Open Make Colon Bajaj, Pt Switch 5slash 6 Amp Bracket Open Make Colon Philips, Pt Switch 15slaash 16 Amp Bracket Open Make Colon Philips, Capacitorfor Ceiling Fan Bracket Open Make Colon V Guard, Fanregulator Bracket Open Make Colon Legrande, Capacitor Forpedestal Fan Bracket Open Make Colon V Guard, Cable 10sqmm 2 Core Aluminium Bracket Open Make Colon Finolex, Change Over Switch 32 Amp Dp Bracket Open Make Colon Land T, Change Over Switch 63 Amp Bracket Open Makecolon L And T, Waste Pipe As Approved Sample, Wastecoupling For Wash Basin Bracket Open Make Colon Supreme, Wash Basin Bracket Open Make Colon Parryware, Cp Pillarcock 15 Mm Bracket Open Make Colon Parryware, Cp Pillarcock Swan Neck 15mm Bracket Open Make Colon Parryware, Pvc Connection 450mm Long As Per Approved Sample, Flush Tank 10 Ltr Capacity Bracket Open Make Colonparryware, Pvc Connection Pipe Bracket Open Make Colonsupreme, Angle Cock 15mm Bracket Open Make Colonparryware, Urinal Waste Pipe Bracket Open Make Colonsupreme, Urinal Pot Large Bracket Open Make Colonsupreme, Shower 20 Mm Bracket Open Make Colonparryware, Pvc Bib Cock 20mm Bracket Open Make Colonsupreme, Cp Bib Cock 15mm Bracket Open Make Colonparryware, Cp Stop Cock 15 Mm Bracket Open Make Colonparryware, Bib Tap 15mm Ptmt Bracket Open Make Colonparryware Slash Hindware, Plastic Tap 15mm Bracket Openmake Colon Supreme, Jet Spray Ewc Bracket Open Makecolon Parryware, Health Faucet Bracket Open Make Colonparryware, Iwc Sheet Bracket Open Make Colon Cera, Ewcsheet With Cover Bracket Open Make Colon Cera, Pvcplastic Hose Pipe 1 Point 5 Inch Dia 50 Mtr Length Bracketopen Make Colon Supreme, Pvc T Joint 40 Mm Bracketopen Make Colon Astral, Pvc T Joint 32 Mm Bracket Openmake Colon Astral, Pvc T Joint 25 Mm Bracket Open Makecolon Astral, Pvc T Joint 20mm Bracket Open Make Colonastral, Gi Elbow 15mm Bracket Open Isi Marked Bracketclose, Gi Elbow 20mm Bracket Open Isi Marked Bracketclose, Gi Elbow 25mm Bracket Open Isi Marked Bracketclose, Gi Elbow 32 Mm Bracket Open Isi Marked Bracketclose, Gi Elbow 40mm Bracket Open Isi Marked Bracketclose, Gi Elbow 50mm Bracket Open Isi Marked Bracketclose, Gi Socket 15mm Bracket Open Isi Marked Bracketclose, Gi Socket 20mm Bracket Open Isi Marked Bracketclose, Gi Socket 25mm Bracket Open Isi Marked Bracket    //bid Details2 / 106 Close, Gi Union 15 Mm Bracket Open Isi Marked Bracketclose, Gi Union 20 Mm Bracket Open Isi Marked Bracketclose, Gi Union 25 Mm Bracket Open Isi Marked Bracketclose, Gi Union 40 Mm Bracket Open Isi Marked Bracketclose, Gate Wall 100 Mm Plasticbracket Open Make Colonsupreme, Ppr Gate Wall 25 Mm Bracket Open Make Colonsupreme, Gate Wall Brass 25 Mm Bracket Open Make Colonleader, Gi Gate Wall 25mm Bracket Open Make Colonsupreme, Gi Gate Wall 32 Mm Bracket Open Make Colonsupreme, Ppr Gate Valve 25mm Bracket Open Make Colonsupreme, Ppr Gate Valve 32 Mm Bracket Open Make Colonsupreme, Ppr Socket 25 Mm Bracket Open Make Colonsupreme, Ppr Socket 32 Mm Bracket Open Make Colonsupreme, Ppr Socket 20 Mm Bracket Open Make Colonsupreme, Ppr Gate Valve 40 Mm Bracket Open Make Colonsupreme, Float Valve 25 Mm Bracket Open Make Colonesssex, Ppr Socket 40 Mm Bracket Open Make Colonsupreme, Ppr Gate Valve 50 Mm Bracket Open Make Colonsupreme, Ppr Socket 50mm Bracket Open Make Colonsupreme, Teflon Tape As Approved Sample, Cp Soap Traybracket Open Make Colon Parryware, Sintex 200 Ltr Bracketopen Make Colon Supreme, Barrel 200 Ltr Plastic Bracketopen Make Colon Supreme, Sintex 500 Ltr Bracket Openmake Colon Supreme, Sintex 1000 Ltr Bracket Open Makecolon Supreme, Plastic Pipe 4 Inch Bracket Open Length 20ft Make Colon Finolex, M Seal As Per Approved Sample, Fevicol Sh As Per Approved Sample, Pvc Hose Pipeconnector Bracket Open Make Colon Supreme, Corner Set 3in 1 As Per Approved Sample, Peg Set 5 Way As Perapproved Sample, Peg Stay Steel As Per Approved Sample, Og Paint Bracket Open Make Colon Asian Paint, White Paintbracket Open Make Colon Asian Paint, Green Paint Bracketopen Make Colon Asian Paint, Wooden Primer Bracket Openmake Colon Asian Paint, Blue Paint Bracket Open Makecolon Asian Paint, Black Paint Bracket Open Make Colonasian Paint, Red Oxide Bracket Open Make Colon Asianpaint, Red Paint Bracket Open Make Colon Asian Paint, Parrot Paint Bracket Open Make Colon Asian Paint, Silverpaint Bracket Open Make Colon Asian Paint, Yellow Paintbracket Open Make Colon Asian Paint, Thinner Bracket Openmake Colon Asian Paint, Water Proofing Paint Bracket Openmake Colon Asian Paint, Paint Brush 1inch As Approvedsample, Paint Brush 3 Inch As Approved Sample, Paintbrush 2 Inch As Approved Sample, Paint Brush 4 Inch Asapproved Sample, Mattress 6 Feet X 3 Feet Bracket Openmake Colon Kurlon, Door 2000 Mm X 1000 Mm As Approvedsample, Nails 1inch As Approved Sample, Nails 2 Inch Asapproved Sample, Nails 4 Inch As Approved Sample, Nails 3inch As Approved Sample, Nails 5 Inch As Approved Sample, Nails 6 Inch As Approved Sample, Bathroom Door 1892 Mmx 737 Mm As Approved Sample, Toilet Door 2000 Mm X 700mm As Approved Sample, Ss Curtain Bracket Bracket Openmake Colon Arena, Ss Curtain Rod 10 Feet Bracket Openmake Colon Arena, Plywood 6 Feet X 3 Feet Bracket Openmake Colon Greenply, Plywood 8 Feet X 4 Feet 6mm Bracketopen Make Colon Greenply, Plywood 8 Feet X 4 Feet 12mmbracket Open Make Colon Greenply, Iron Cutter Blade 4 Inchbracket Open Make Colon Bosch, Saw Iron Blade Bracketopen Make Colon Bosch, White Cement Bracket Open Makecolon Jk, Latch As Approved Sample, Latch Hook Asapproved Sample, Door Stopper Bracket Open Make Colongodrej, Binding Wire As Approved Sample, Mirror Lookingas Approved Sample, Door Handle As Approved Sample, Cgi Sheet 06 Feet Bracket Open Make Colon Tata, Cgi Sheet    //bid Details3 / 106 Feet Bracket Open Make Colon Tata, Cgi Sheet 10 Feetbracket Open Make Colon Tata, Cgi Sheet 12 Feet Bracketopen Make Colon Tata, Ppgi Sheet Of Size 10 X 3 Point 5 Ftbracket Open Make Colon Tata, Septic Tank And Soakage Pit300 Ltr Bracket Open Make Colon Finolex, Tarpaulin 15 Feetx 18 Feet As Approved Sample, Hdpe Sand Bag As Perapproved Sample, Green And White Translucent Fabricsheet 8 Feet As Per Approved Sample, Pbs Roll Of 3 Mtr X 25mtr As Approved Sample, Cement Bag Bracket Open Makecolon Jk, Fiber Sheet Mirror Type Bracket Open Make Colonroca, Wire Mesh 4 Feet X 100 Feet Bracket Open Make Colontata, Acrylic Sheet 6 Feet X 4 Feet Of 4 Mm Thick As Perapproved Sample, Self Tapping Screw 2 Inch As Perapproved Sample, Self Tapping Screw 1 Point 5 Inch As Perapproved Sample, Self Tapping Screw 3 Inch As Perapproved Sample, Water Dispensar Bracket Open Makecolon Voltas

Ref. Document
View Tender
#TBR: 35379519 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Starter, Main Switch And Capacitor Inside The Pannel Board Vertically Over 18 Swg M.s. Sheet. The Pannel Board Should Be Provided With Locking Arrangement And Have Grover On Rear Side For Fixing Motor Hood. The Danger Board Should Be Fixed On The To Of The Pannel Door. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required

14.55 Lacs
View Tender
#TBR: 35379561 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Starter, Main Switch And Capacitor Inside The Pannel Board Vertically Over 18 Swg M.s. Sheet. The Pannel Board Should Be Provided With Locking Arrangement And Have Grover On Rear Side For Fixing Motor Hood. The Danger Board Should Be Fixed On The To Of The Pannel Door. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required

14.60 Lacs
View Tender
#TBR: 35379659 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required

14.99 Lacs
View Tender
#TBR: 35381009 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required

14.68 Lacs
View Tender
#TBR: 35381018 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia C.i Reflux Valve(nr) 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Star 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4.0 Mm 2 Pvc Single Core Copper Wire

6.97 Lacs
View Tender
#TBR: 35381035 Closed

Canal/irrigation/dam Work

  • Orissa
  • Due On: 25 Sep, 2025 (0 Days Left)

Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required

14.70 Lacs
View Tender
Download Document