Design, Supply, Erection, Installation, Testing And Commissioning Of 01 One No. Of Air-cooled Heat Exchanger Ache For Dresser Rand Make Gas Compressor Unit 8
Design, Supply, Erection, Testing And Commissioning Of 1950 Cfm Refrigerated Air Dryer Co Mprising Of Followings: A Air-To-Air Exchanger B Air Cooled Condenser C Evaporator D Compressor E Prefilter F Final Filter G Auto Drain Valve & Control Equipment & Along With Associated Parts. H Digital Fl Ow Meter For Measuring Quantum Of Air Output From Air-Dryer In Cfm, Control Equipments & Along With Ass Ociated Parts Of The System In Complete Set As Per Attached Technical Specification No. Rwf/El/P/Specn-24 /Wsp/Air Dryer Dtd: 08/08/2024. Comprehensive Annual Maintenance Contract For The Above Machine For A Perio D Of Five 5 Years Post Warranty As Per Annexure-A Of Specification. Warranty Period Is 24 M Onths From The Date Of Commissioning. Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 %
Replacement Of Evaporator Heat Exchanger Of 60Tr Air Cooled Chiller Plant Bearing Serial No. 2115-Go7 And Other Allied Electrical Repair Work Of Plant At Goa Niwas, Chanakyapuri, New Delhi.
Cleaning Of Air Cooled Heat Exchanger Of Gtg 3
Custom Bid For Services - Foam Cleaning Of Air Cooled Heat Exchanger Of Gtg Iii
Repair And Maintenance Of Plant Systemsequipments - Refinery And etrochemicals; Mrpl Tender No 3300010845 And Service Code 1022587 For Dcu Heat Exchanger Overhauling As Per Sow And Section G And In Gem Overall Total Lump Sum Rate To Be Quoted Cons.. Repair And Maintenance Of Plant Systemsequipments - Refinery And Petrochemicals; Service Code 1022588 For Dcu Air Cooled Exchanger Overhauling As Per Sow And Section G And In Gem Overall Total Lump Sum Rate To Be Quoted Considering 1900 Nos Of Tube..
Supply Installation Testing And Commissioning Of Air Cooled Heat Exchanger Vv Type Including Piping Work Electrical Cabling Panel Installation And Other Allied Work Suitable For 1010 Kva Cummins Dg Set At Substation No 2 Of Iit Ism Campus
Supply of Coil Spring For Hold Down Of Shearing Machine Plant No.- 10908/Bst As Per Sketch No.- Mts/08/Skb/87, Dated- 10/10/2023, Material:- Is:31951992.Size:- Height/Length-96 Mm, Outside Diameter-76 Mm, Inside Diameter- 60 Mm, Core Dia-08 Mm, No. Of Turn- 12 Nos., Working Pressure- 20 Mpa. Warranty Period: 30 Months After The Date Of Delivery Air Cooled Heat Exchanger For Hydraulic Power Pack Of 200 Tonnes Press Machine.Oil Tank Capacity -80 Liters, Power Pack Motor Power- 3.7 Kw, Power Pack Pump Flow Rate- 4.3 Lpm And Cooling Capacity Of Heat Exchanger -5000 Kcal/Hrs. Warranty Period: 30 Months After The Date Of Delivery
Supply of 1 Air Cooled Heat Exchanger Cg3900901180 Q3
Supply Installation Testing And Commissioning Of Air - Cooled Heat Exchanger, Vv Type Including Piping Work, Electrical Cabling, Panel Installation And Other Allied Work Suitable For 1010 Kva Cummins Dg Set At Substation No - 2 Of Iit Ism Campus.