Gem Bids For Mouse, Internal Dvd Writer, Drum, Power Cable, Pressure Roller
Gem Bids For Tie Rod End Lh, Terminal Lug Positive, Sensor Waterseparater, Pad, Wipper Linkage Assy, Retainer Oil Seal, Front Brake Cable, Drum Plate, Lever Comp R Stearinghandle
Gem Bids For Procurement Of Cable Reeling Drum For Tong As Covered Asper Technical Specifications., Procurement Of Air Conditionsystem For Electrical Panel Cabin As Covered As Pertechnical Specif, Procurement Of Terminal Box On Bridgeand Main Trolleytbbm/tbtm As Covered As Per Technicalspec, Procurement Of Armchair Control Unit As Covered Asper Technical Specifications, Procurement Of Lightingdistribution Board As Covered As Per Technicalspecifications.
Gem Bids For E, 1 . 88580003800 Plummer Block Snl 516-613 With Feltseals And Locating Ring Plummer Block Size Snl 516 -613 With Felt Seals And Locating Ring, 2 .88580002850 Plummer Block Snl 520-617Plummerblock Snl 520-617 Plustwo Nos. Of Double V Sealtsn520g, 3 . 88606209180 Deep Groove Ball Brg 6209Zbtc And Ctc Track Wheel Bearing, 4 . 88606205560 Deepgroove Ball Brg. 6205-2Zcarrying Idlers Bearing, 5 .88606309260 Deep Groove Ball Bearing 6309 2Zdia457 And Dia 305 Steel Pulley Bearing, 6 . 88622220110Spherical Roller Bearing 22220 Cc-W33 By 22220 Esby Estvpb Modified Belt Drum Of Cable Belt Conveyor, 7 .88623136410 Spherical Roller Bearing 23136 Cck Byw33fc Drive Pulley Bearing, 8 . 88822224170 Bearingno. 22224 Ec3 By Ccw3 C3fc Tail Pulley, 9 . 88622232140Sph.Roller Brg.22232 Cck By 22232 Ck By W33ac Drivepulley By Fc Snub Pulley, 10 . 88570009610 Adaptorsleeve H-3132 Ac And Fc Pulley Sleeve, 11 . 88681003280Lock Nut No- Km 32Ac And Fc Pulley Lock Nut, 12 .88680032010 Adapter Sleeve H-320 With Lock Nut Andlock Washerac Tail Pulley Sleeve H320, 13 .88870061060 Adaptor Sleeve H-3152Astream 01 Apronfeeder 01 Sleeve, 14 . 88612035980 Spherical Rollerbearing No-23130 Cckst01af02 Drive Shaft Lube End Bytail Wheel, 15 . 88623140440 Bearing-23140 Cck By W33st01af02 Counter Shaft, 16 . 88599436550 Bearing Ucx-20 Cable Belt Conveyor Belt Drum, 17 . 88595002540 Brg.23148St01af02 Drive Shaft Motor End
Gem Bids For Tp Link 8 Port Giga Poe, Secure Eye Media Convertergiga, Fibre Optic Cable, Cat 6 Cable 305 Mtr Drum, Pipes And Fitting, 4 By 4 Pvc Box, Installation Andcalibration Charges, Sike Buster 5 Mtr, Cp Plus 2urack, Delivery Charges, Seagate 4tb Hdd Sv, Rj 45jack, Fibre Slicing, Black Box Fibre, Sc Jack Fibre
Gem Bids For It, 24 Port Switch Layer 2 Manageable Sfp Ports, Utp Cablecat 6 Drum 305, Hdmi Cable 05 Mtr, Hdmi Cable 10, Hdmicable 15 Mtr, Hdmi Cable 20 Mtr, Hdmi Cable 25 Mtr, Hdmi Cable 50, External Dvd Writer, Ups 5 Kva Online
Gem Bids For Procurement, Dual Dc Supply Switches With 24 Lan Ports And 4 Sfp Portsmake- Moxa Model- Iks 6728A-4Gtxsfp 24-24-T, Dual Acsupply Switches With 24 Lan Ports And 4 Sfp Ports Type-Imake-Moxa Model-Iks 6728A-4Gtxsfp Hv-Hv-T, Dual Acsupply Switches With 24 Lan Ports And 4 Sfp Ports Type-Iimake-Moxa Model - Iks 6728A-4Gtxsfp Hv-Hv-T, Dual Dcsupply 12-48Vdc Router Make- Moxa Model- Edr-G903, Compatible Lc Type Sfp Adaptors, Lc To Lc Single Modepatch Chord, Lc To Sc Single Mode Patch Chord, Cat 6Autp Lan Patch Chords - Red Colour, Cat 6A Utp Lan Patchchords -Yellow Colour, Standard 305 Meters Cat-7 S Ftp Lancable Drum, Console Cable Interface - Usb-Serial Consoletype B Connector, Console Cable Interface - Web-Telnet-Ssh-Cli And Rs-232 Serial Console
Gem Bids For Pa Amplifier, Pagingmicrophonecord Typedesktopmodel, 10 Zone Selector Audio Console, Speakerwallmounting Public Address Sys, Assembled Syscabinet W Accessories, Copper Wire, Electrificationand Cable Laying Charge With Casing And Capping, Installation, Testing, Programming, Commisioing Andtraining Charge, Cat 6 Stp Cable Drum
Gem Bids For Motorized, 1 Yard-3037-3038 Motorized Shore Supply Cablehandling And Stowage System Mc-712501000000, 2 Yard-3037-3038 Installation Material Mc-712501950000, 3 Yard-3037-3038 Obs For 2Years Mc-712501970000, 4 Yard-3037-3038 Documentation For Cable Reeling Drum Mc-712501990004, 5 Yard-3037-3038 Service Ofengineer Mc-Ser11020, 6 Yard-3039-3040 Motorizedshore Supply Cable Handling And Stowagesystem Mc-712501000000, 7 Yard-3039-3040 Installation Material Mc-712501950000, 8 Yard-3039-3040 Obs For 2 Years Mc-712501970000, 9 Yard-3039-3040 Documentation For Cable Reelingdrum Mc-712501990004, 10 Yard-3039-3040 Serviceof Engineer Mc-Ser11020
Gem Bids For Flexible, Item 10, Item 20, Item 30, Item 40, Item 50, Item 60Cable, Trg, Atc, 3.3Kv Gr, 3.5Cx50mm2, Is9968 Size & Tvpe3.5Cx50 Sq. Mm 3.3 Kv Grade Flexible Atc Conductorof Class-S, Epr Le-3, Insulated &Black Hofr Nbr Pvctype Se-4 Sheathed Flexible Trailing Cable Suitablefor Reeling/Un-Reeling Operation. Cable Type-Flexible, Standard: Is 9968Part 2 2002 D.C.Resistance At 20Deg. C Ohms/Km Power Core Max-0.393 Earth Core Max - 0.795. Annealing Test In %-Before Stranding 13.5 %. Per Sulphate Test In G/M2-Max. 5.00. Conductor Screeninq Power Core Onlymaterial Approx Thickness Mm - Extrudedsemiconducting Compound/ Extruded Semiconducting Tape- 0.80. Conductor Material:Annealed Tinned Copper, 6.6 Klv Grade, Cable Type:Flexible, Standard: Is 9968Part 2 2002 Tests Oninsulation Thickness Nom Mm Core Ldentification -Power Core-2.20 Colour Rpct Red, Yellow & Blue Forpower Cores & Green For Earth Core Tensilestrength Before Ageing N/Mm2- Min.4.20 % Variationafter Ageing Air Oven- Max. +-30% % Variationafter Ageing In Air-Bb- Max. +- 30%. Elongationbefore Ageing In % - Min.200% % Variation Afterageing Air Oven- Max. +- 30% % Variation Afterageing In Air-Bb- Max. +- 30%. Hot Set Test Hot Setelongation- 175% Permanent Set 15%. Lnsulationresistance Constant Min. M Ohm Km. At 27Deg.C-Min. 3670 At 90 Deg.C-Min 3.67. Thick Of Lnner Sheathmin 2.00 Mm. Rein Forcement- Open Braid Of Textilematerial Physical Test On Outer Sheath Thicknessnom / Min Mm- 3.50/ 2.60 Colour Black, Over Alldiameter Of Cable Mm- 52.00+-3.00. Tensile Strength /Bid Number: Gem/2025/B/6811700* /Dated: 24-10-2025 & & / Bid Document1 / 22 Before Ageing N/Mm2 - Min. 11.0 At 2Oo Elongation 4N/ Sq. Mm. % Variation After Ageing In Air-Bb-Max.+- 50% Elongation Before Ageing In %- Min.250% %Variation After Ageing In Air-Bb- Max. + 50%. Hotset Test Hot Set Elongation- Max.175% Permanentset- Max 15. Oil Resistance Test Variation In % Intensile Strength- Max. +-40% Variation In % Inelongation-Max. +-40%. Tear Resistance In N/Mm -Min.5.0. Flammability Test Period Of Burning Afterremoval Of Flame- Max. 60 Sec. Min Unaffectedportion From The Lower Edge Of The Top Clamp - Min50 Mm. Test High Voltage At Room Temp- 10 Kv Ac For4 Hours. Water Absorption Test Increase Incapacitance 1 To 14 Days Max- 6% 7 To 14 Days Max-2.5%., Control Trailing Cable 12 C X 2.5 3 P X 1.5 Pairscreened 2 Voltage Grade 1.1 Kv 3 Referencestandard Generally Confirming To Is: 9968 Part-11998 4 Conductor A. Material To Is:8130/84Annealed Tinned Copper B. Nominal Area Of Crosssectionsq. Mm I-Unscreened Core Sq. Mm. 2.5 Ii -Screened Pair Sq. Mm. 1.5 C. Flexibility Class As Peris:8130/84 Class-5 D. Maximum Dc Resistance Ofconductor At 20 Deg. C I-Unscreened Coreohms/Km 8.21 Ii- Screened Pair Ohms/Km 13.7 5Insulation I Material Epr Type Ie-2 To Is:6380/84 Iinominal Thickness Mm 1.0 6 Two Cores Of 1.5 Sq.Mm. Size Twisted Together To Form A Pair Yes. 7Individual Pair Screening Each Pair Of 1.5 Sq. Mm.Size Taped With Rpct, Screened With 0.2 Mm Nom Diaof Annealed Tinned Copper Wires Braid, Taped Withmelinex Tape. Yes. 8 No Of Cores / Pair I-Unscreenedcores 12 Ii-Screened Pairs 3 9 Identification Ofpower Cores By Number Printing On Cores. 10 Layingup I Three Screened Pairs Laid Up Together, Tapedwith Rubber Proofed Cotton Tape To Form Group Asa Ii 12 Unscreened Control Cores Laid Uptogether Around Group As A Of Screened Pairsand Taped With Rubber Proofed Cotton Tape Appliedwith Open Spiral. 11 Inner Sheath A Material To Is:6380/84 Hd Hofr Csp Type Se-4 B Minimum Thicknessmm 1.6 12 An Open Braid Of Nylon Cord Reinforcedin Between Inner And Outer Sheath. Yes. 13 Outersheath A Material To Is: 6380/84 Hd Hofr Csp Typese-4 B Nominal Thickness Mm 2.5 14 Nom. Overalldiameter Of Cable Mm 33.0 Tolerance On Nom.Overall Diameter Mm /- 2.0 15 Max. Safe Pullingtension Load For Reeling And Unreeling Duty Kgs60 16 Current Rating In Air And Ambient Temp 40 Deg.C Amp 14 17 Derating Factors For Variation In Airtemp 18 Temp Deg. C 30 35 40 45 50 55 Ratingfactors 1.12 1.06 1.0 0.94 0.86 0.80 Derating Factorfor No Of Layers In Reeling Drum 19 No Of Layersmono-Spiral 2 3 A Rating Factor 0.76 0.58 0.47 Brecommended Minimum Bending Radius 12 X Overalldiameter Of Cable. 20 Approx. Weight Of Cablekg/Km 1340.0 21 Drum Length Of Cable Withtolerance Meters 1X210, 5 22 Required Quantity Insingle Piece, Flexible Trailing Composite Power Andcontrol Cable. 4 C X 35 4 C X 2.5 3 P X 1.5 Pairscreened Voltage Grade 1.1 Kv Referencestandard Generally Confirming To Is: 9968 Part-11998 Conductor Material Annealed Tinned Copperas Per Is:8130/84 Nominal Area Of Cross Section Sq.Mm I Power Core. 35 Ii Earth Core. 35 Iii - //Bid Details2 / 22