Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Construction Of Embankment With Material Obtained From Borrow Pits Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305 Carriage Of Material From Quarry / Crusher To Work Site Including Loading, Unloading And Stacking All Complete. Earth, Sand, Lime, Morrum Manure Or Sludge For 5.05 Km. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Dismantling Of Cement Concrete Pavements As Per Morth Specification Clause 202. Dismantling Of Cement Concrete Pavements By Mechanical Means Using Pneumatic Tools Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Upto A Lead Of 1000 M, Stacking Serviceable And Unserviceable Materials Separately Harnawda Shahji To Kachnariya Khurd Km. 1/500, 1/800, 2/500
Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 P.c.c. M 15 Ordinary Grade (1:2.5:5) Levelling Course Below Approach Slab Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Nominal Mix (1:2.5:5) Reinforced Cement Concrete M 25 Grade Approach Slab Including Reinforcement And Formwork Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Fillling Joint Sealing Compound As Per Drawings And Morth Specifications With Coarse Sand And 6 Per Cent Bitumen By Weight Clause 2604 Drainage Spouts Complete As Per Drawing And Morth Specifications Clause 2705 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Stone Masonry, Including Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lift And Lead Of 1000 M As Per Morth Specification Clause 202. Rubble Stone Masonry In Cement Mortar Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Dismantling Of Cement Concrete Pavements As Per Morth Specification Clause 202. Dismantling Of Cement Concrete Pavements By Mechanical Means Using Pneumatic Tools Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Upto A Lead Of 1000 M, Stacking Serviceable And Unserviceable Materials Separately Clearing And Grubbing Road Land Including Uprooting Wild Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Of Girth Upto 300 Mm, Removal Of Stumps Of Such Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To Be Used Or Auctioned, Upto A Lead Of 1000 M Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Per Morth Specification Clause 201. By Mechanical Means In Area Of Thorny Jungle Gangti To Padaliya Road Km. 0/050
Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 P.c.c. M 15 Ordinary Grade (1:2.5:5) Levelling Course Below Approach Slab Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Nominal Mix (1:2.5:5) Reinforced Cement Concrete M 25 Grade Approach Slab Including Reinforcement And Formwork Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Fillling Joint Sealing Compound As Per Drawings And Morth Specifications With Coarse Sand And 6 Per Cent Bitumen By Weight Clause 2604 Drainage Spouts Complete As Per Drawing And Morth Specifications Clause 2705 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Stone Masonry, Including Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lift And Lead Of 1000 M As Per Morth Specification Clause 202. Rubble Stone Masonry In Cement Mortar Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Dismantling Of Cement Concrete Pavements As Per Morth Specification Clause 202. Dismantling Of Cement Concrete Pavements By Mechanical Means Using Pneumatic Tools Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Upto A Lead Of 1000 M, Stacking Serviceable And Unserviceable Materials Separately Haranwada Shahaji To Footibarod Km. 0/200
Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 P.c.c. M 15 Ordinary Grade (1:2.5:5) Levelling Course Below Approach Slab Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Nominal Mix (1:2.5:5) Reinforced Cement Concrete M 25 Grade Approach Slab Including Reinforcement And Formwork Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Fillling Joint Sealing Compound As Per Drawings And Morth Specifications With Coarse Sand And 6 Per Cent Bitumen By Weight Clause 2604 Drainage Spouts Complete As Per Drawing And Morth Specifications Clause 2705 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Stone Masonry, Including Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lift And Lead Of 1000 M As Per Morth Specification Clause 202. Rubble Stone Masonry In Cement Mortar Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Construction Of Embankment With Material Obtained From Borrow Pits Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305 Carriage Of Material From Quarry / Crusher To Work Site Including Loading, Unloading And Stacking All Complete. Earth, Sand, Lime, Morrum Manure Or Sludge For 5.05 Km. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Dismantling Of Cement Concrete Pavements As Per Morth Specification Clause 202. Dismantling Of Cement Concrete Pavements By Mechanical Means Using Pneumatic Tools Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Upto A Lead Of 1000 M, Stacking Serviceable And Unserviceable Materials Separately Providing And Laying Reinforced Cement Concrete Pipe Np3 For Culverts On First Class Bedding Of Granular Material In Single Row Including Fixing Collar With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2905. 1000 Mm Dia Nh 90 To Nalkheri Km. 0/500
Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 P.c.c. M 15 Ordinary Grade (1:2.5:5) Levelling Course Below Approach Slab Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Nominal Mix (1:2.5:5) Reinforced Cement Concrete M 25 Grade Approach Slab Including Reinforcement And Formwork Complete As Per Drawing And Morth Specifications Clauses 1700 And 2704 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Fillling Joint Sealing Compound As Per Drawings And Morth Specifications With Coarse Sand And 6 Per Cent Bitumen By Weight Clause 2604 Drainage Spouts Complete As Per Drawing And Morth Specifications Clause 2705 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Stone Masonry, Including Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lift And Lead Of 1000 M As Per Morth Specification Clause 202. Rubble Stone Masonry In Cement Mortar Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Construction Of Embankment With Material Obtained From Borrow Pits Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305 Carriage Of Material From Quarry / Crusher To Work Site Including Loading, Unloading And Stacking All Complete. Earth, Sand, Lime, Morrum Manure Or Sludge For 5.05 Km. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Dismantling Of Cement Concrete Pavements As Per Morth Specification Clause 202. Dismantling Of Cement Concrete Pavements By Mechanical Means Using Pneumatic Tools Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Upto A Lead Of 1000 M, Stacking Serviceable And Unserviceable Materials Separately Providing And Laying Reinforced Cement Concrete Pipe Np3 For Culverts On First Class Bedding Of Granular Material In Single Row Including Fixing Collar With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2905. 1000 Mm Dia Tancha To Falia Via Aznawar Km. 3/900 Bhagwanpura Village
Sh - Providing And Laying Of Granite Stone Blocks On Rmc Of Grade M-30 Including Dismantling Of Existing Cement Concrete Pavement At The Main Entrance Of Khan Market At Subramanium Bharti Marg. Repair And Maintenance Of Infrastructure Assets In R-Ii Division During 2025-26.
Replacing Of Old And Damaged Stop Log Gate Foundation, Anchor, Plate, Bolt Dismantling Of Old Concrete And Replacing Of Flat, Anchor, Plate Proper Aligning And Grouting, Cutting, Welding And Base Concrete Etc Masonary Dam Rajghat
Gem Bids For Operation, O And Monitoring Of Fhs And Fas Comprehensivemaintenance Of Fire Alarm And Smoke Detection Systemfirst Year Comprehensive Maintenance Of Fire Alarm Andsmoke Detection System Second Year Inspection Servicecontract For Kirloskar Make Diesel Engines First Year Inspection Service Contract For Kirloskar Make Dieselengines Second Year Dismantling Of Existing Split Case Orradially Split Case Type Centrifugal Pump Sets Mainelectrical Pump 75 Hp Or 171 Cum Or Hr Mather Platt Make Dismantling Of Existing Split Case Or Radially Split Case Typecentrifugal Pump Sets Diesel Pump 72 Hp Or 171 Cum Or Hrmather Platt Make Dismantling Of Existing Split Case Orradially Split Case Type Centrifugal Pump Sets Jockey Pump10 Hp Monoblock Suguna Make Dismantling Of Valvesfrom The Existing Fire Fighting Water Pipe Line Sitc Of Cclass Heavy Duty Ms Pipe Fixing The Pipe On The Wall Orceiling 80 Mm Sitc Of C Class Heavy Duty Ms Pipe Fixingthe Pipe On The Wall Or Ceiling 100 Mm Sitc Of C Classheavy Duty Ms Pipe Fixing The Pipe On The Wall Or Ceiling 150mm Sitc Of C Class Heavy Duty Ms Pipe Fixing The Pipe Onthe Wall Or Ceiling 200 Mm Sitc Of C Class Heavy Duty Mspipe Fixing The Pipe Which Are Under The Ground Under Alltypes Of Flooring 80 Mm Sitc Of C Class Heavy Duty Mspipe Fixing The Pipe Which Are Under The Ground Under Alltypes Of Flooring 100 Mm Sitc Of C Class Heavy Duty Mspipe Fixing The Pipe Which Are Under The Ground Under Alltypes Of Flooring 150 Mm Sitc Of C Class Heavy Duty Mspipe Fixing The Pipe Which Are Under The Ground Under Alltypes Of Flooring 200 Mm Dismantling Of Old Orunserviceable Butterfly Valves Supplying Fixing Testingand Commissioning Of Wafer Type Butterfly Valve 50mm Diapn 16 Rated Supplying Fixing Testing And Commissioningof Wafer Type Butterfly Valve 80mm Dia Pn 16 Rated Bid Number Gem2025b6853679 Dated 04-11-2025 Bid Document1 55 1 1 Supplying, Fixing, Testing And Commissioning Of Wafer Typebutterfly Valve 100mm Dia Pn 1.6 Rated, Supplying, Fixing, Testing And Commissioning Of Wafer Type Butterfly Valve150mm Dia Pn 1.6 Rated, Supplying, Fixing, Testing Andcommissioning Of Wafer Type Butterfly Valve 200mm Dia Pn1.6 Rated, Supplying And Fixing The Following Size Of Nonreturn Valves 50 Mm Non Return, Supplying And Fixing Thefollowing Size Of Non Return Valves 80 Mm Non Return, Supplying And Fixing The Following Size Of Non Return Valves150 Mm Non Return, Dismantling The Following Size Of Nonreturn Valves 50mm Or 80mm Or 100 Mm Dia Non Return, Dismantling The Following Size Of Non Return Valves 150mmor 200mm Dia Non Return, Supplying And Fixing Thefollowing Size Of Foot Valves 100 Mm Dia, Supplying Andfixing The Following Size Of Foot Valves 200 Mm Dia, Supplying, Fixing, Testing And Commissioning Of Installationcontrol Valve, Supplying And Fixing Of Gate Valve 0.5 Inch, Supplying And Fixing Of Gate Valve 1 Inch, Supply Andreplacement Of 1 By 2 Inch Pipe Dia Pressure Gauges, Supply And Replacement Of Pressure Switch, Wrapping Ofexisting Mild Steel Pipe, Supply And Fixing Of 25mm Gm Airrelease Valve, Suppy And Fixing Of Hose Reel Drum Set, Supplying And Fixing Of Hose Reel Nozzle, Supplying Andfixing Of Cotton Linen Hose, Supplying And Fixing Of Suitableglass, Providing And Fixing Of Single Headed Fire Hydrantlanding Valve, Providing And Fixing Of Repeater Panel, Fabrication, Supply And Fixing Of M.s Work, Providing Onewelder And One Khalasi, Disconnecting And Dismantling Ofburnt Out Induction Motor 55kw, Disconnecting Anddismantling Of Burnt Out Induction Motor 7.5 Kw Or 10 Hpmonoblock, Painting Of Metals Surfaces Or Pipes Orstrucutres, Earth Work All Types Of Soil In Excavation, Demolishing Cement Concrete, Dismantling Manually Or Bymechanical Serviceable Material And Disposal Ofunserviceable Material, Earth Work In Excavation, 12 Mmcement Plaster, Filling Available Excavated Earth Excludingrock In Trenches, Providing And Laying In Position Cementconcrete, Brick Work With Common Burnt Clay, Reinforcedcement Concrete Work, Steel Reinforcement For R.c.c. Work, Centering And Shuttering Including Strutting, Propping, Supply Of Concrete Closing Lid, Supply Of Metal Plate Closinglid, Sitc Of Ul Or En Loop Powered Addressable Hooter-cum-strobe, Sitc Of Ul Or En Loop Powered Addressable Isolatormodule, Supply Of 2 Core 1.5 Sq.mm Copper Conductor, Laying Of 2 X 1.5 Sqmm Frls Cable, Supply Of B-checkspares Koel Care Super Genuine Oil, Supply Of B-checkspares Spinon Lube Oil Filter, Supply Of B-check Sparesfuel Filter Kit 1.1 Ltr, Supply Of Addressable Fire Alarm
Provisions Included In This Work Are Rectified Ceramic Tile Epoxy For Tile Dismantling Toilet Tile Dismantling Concrete Cc 124 For Concrete Water Proofing For Toilet Acid Washing Floor Mount Ewc Health Faucet Long Body Tap High Court Of Kerala Modification And Repairing Of Judges Chambers
Gem Bids For Renovation, Supply And Fixing Glass Partition, Supply And Fixingglass Door, Supply And Fixing Frosted Film, Supply Andfixing Flush Door S, Supply And Fixing Metal Fire Rated Door, Supply And Fixing Upvc Fixed Glazed Windows, Supply Andfixing Roller Blinds, Supply And Fixing Wall Pannelling Work, Supply And Fixing Of Wallpapers, Supply And Fixing Officeplanters, Supply And Fixing Gypsum Partition, Supply Andfixing Gypsum False Ceiling System, Supply And Fixingvitrified Tiles, Supply And Fixing Granite Slabs, Supply Andfixing Stainless Steel Kitchen Sink, Supply And Fixing Sinkcock, Supply And Fixing Plumbing Jobs, Supply And Fixingpainting Works, Supply And Fixing Exterior Emulsion Paint, Supply And Fixing Patient Steel Cot, Supply And Fixingceiling Light, Supply And Fixing Cove Light, Supply And Fixingprofile Light, Supply And Fixing Modular Switch Board, Supply And Fixing False Ceiling Wiring, Supply And Fixing Fullheight Storage, Supply And Fixing Over-Head Storagecabinets, Supply And Fixing Half Height Storage, Supply Andfixing Low Level Storage, Supply And Fixing L Shapedworkstation, Supply And Fixing Cabin Table, Supply Andfixing Flipopen 450Mm X 150Mm Cabin Table, Supply Andfixing Prelam Pedestal On Castors For Above Mentionedtables, Supply And Fixing Modular Partitions, Supply Andfixing Running Counter, Supply And Fixing Prelam Pedestalon Castors For Running Counter, Supply And Fixing Stainlesssteel Railing, Supply And Fixing Illluminating Bpcl Logo, Dismantling Aluminium, Removing Of Existing False Ceiling, Demolition Of Floor Tiles, Dismantling Of Reinforcedcement Concrete, Dismantling Brick Masonry, Providingarchitectural Consultancy Services