Tender Bharat Website covers all Tenders for connecting strip – Including connecting strip Government Tenders, e Tender connecting strip, connecting strip Tenders and Private Tenders. There is no shortage of business opportunities from the largest connecting strip Tender Database.
Our website allows you to find connecting strip tenders online quickly and easily. Subscribers can also opt to receive daily tender alerts through email from TenderBharat.com to guarantee they don't miss out on any opportunities.
Gem bids for Spares For Furnace Vacuum Graphite With Edwards Rotary Pump, 67 Feed Through Fixing Block Part No. 2304-003-002 Front Support Block-1 Part No. 2304-003-003 Front Support Block-2 Part No. 2304-003-006 Front Support Block-3 Part No. 2304-003-007 Heating Element Part No. 2304-003- 004 Power Feed Through Body-1 Part No. 2304-003-001 Power Feed Through Body-2 Part No. 2304-003-005 Rear Block-1 Part No. 2304-003-020 Rear Block-2 Part No. 2304-003-021 Rear Block-3 Part No. 2304-003-025 -1 Part No. 2304-003-022
Providing Copper
Supply of
Supply of
Supply of Set Of
Supply of 16 33Kv Ct
Supply Of Washer, Lock Pin, Boss, Packing Plate, Spherical Bush, Screen, Pin, Gasket, Sealing Ring,
Supply of Lightening Arrestor Supply Of Metal Oxide Lightning Arresterla Heavy Duty Station Class Metal Oxide Gapless Lightning Arrester Morester Type Stn-D Type Heavy Duty Station Class Metal Oxide Gaples S Lightning Arrester Morester Type Stn-D Reference Standard Iec 99-4 Of 2006/Is 3070 Part3 1993 No Of Unit One Rated Voltage 30Kv Nominal Discharge Current With Class 10Ka Class 1 Reference Current 2 Ma Pea K Reference Voltage Greater Than Rated Arrester Voltage At Reference Leakage Current At Cov Less Than 0.8 Ma M Ax Continuos Operating Voltage 24Kv Rms Maximum Residual Voltage For Discharge Current Of 8/20 Micro Sec Wav E 5000 Amps 85Kvpeak 10000 Amps 90Kvpeak 20000 Amps 100Kvpeak Max Steep Front Residual Voltage At 10 Ka With One Micro Sec Rise Time 100Kvpeak Max Switching Impulse Residual Voltage With 40/80 Us Wave At 1000 A Mps 80Kvpeak Energy Dissipation Capability Form 3 Seqential Shots 6 Kj /Kv High Current 4/10 Us Test Value 100Ka Peak Long Duration Current Tests Current Peak Virtual Duration As Per Discharge Class 2 Of Iec -99-4 Table -4 200 0 Micro Sec Pressure Relief Class Class A Short Circuit Current Capability 40Ka Rms Partial Discharge At 1.05 Time S Mcov Less Than 10Pc 0.1 Second 34.5Ka Rms 0.1 Second 33.5Ka Rms 10.0 Second 31.5Ka Rmsinsulation Withst And Tests On Arrester Housing One Minute 50 Hz Dry & Wet 95Ka Rms Lightning Impulse Voltage Withstand 175Ka R Ms Creepage Distance Mm 900 Nominal Weight Of Complete Unit 11?10% Kgs Height Of Complete Unit From Bas E To The Line Side Refer Drg No 2500300 Minimum Recommended Contre To Centre Spacing Between Arresters500 Mm Clearance Required Form Ground Equipment At Various Heights Of Arrester 400 Mm Earthing Arrangement Pro Vided For Earthing Side Of Arrester Ground Terminal Bracket Provided For
Providing And Fixing Lightening Arrestors And
Providing And Fixing 23 Nos. Aviation Lamp For Towers And 66 Nos. Lightening Arrestors And