"नये भारत का नया Tender Portal"
Request a call back

Latest Tenders for fibre board

Total 380 tenders found
#TBR: 36276785 Live

Security Services

  • Uttar Pradesh
  • Due On: 12 Jan, 2026 (0 Days Left)

Gem Bids For Box Fibre Board Rigid Corrugated Double Wall 5 Plysize 420Mm X 330Mm X 375Mm, Box Fibre Board Rigidcorrugated Triple Wall 7 Ply Size 700X 450X400mm

4.76 Lacs
View Tender
#TBR: 36196418 Closed

Electrical Products

  • Karnataka
  • Due On: 30 Dec, 2025 (0 Days Left)

Gem Bids For Supply Of Ceramic Fibre Board

Ref. Document
View Tender
#TBR: 36154432 Closed

Security Services

  • Punjab
  • Due On: 25 Dec, 2025 (0 Days Left)

Gem Bids For Adapter For Ptz Camera , Labour , Bullet Ip Camera , 12v 5 Amp Adapter , Patch Caste , Joint Box , Pvc Pipe , Rj 45 Connection , Cat 6 Meter , Power Caste , Extension Board , Pvc Box , Fibre Joint , Installation , Ic Based Extension Board

Ref. Document
View Tender
#TBR: 36106999 Closed

Security Services

  • Punjab
  • Due On: 22 Dec, 2025 (0 Days Left)

Gem Bids For H1 (b) 7930-000002 Polish Wax, H1 (b) Adhesive Sys Resin Araldite Ay-103, H1 (b) 8520-000004 Soap Shaving Table, H1 (b) 9150-000143 Soap Soft, H2 4020- 000138 Rope Hawserlaid Rot Proofed Undyed 38 Mm, H2 8305-000044 Cloth Bunting India Green 145 Cm, H2 8305-000509 Cloth Muslin Blue 91 Cm Wide, H2 4020- 000120 Cord Cotton Undyed 2mm Dia, H3 5530-400102 Ply Wood For General Purposes Mr-ab 7, H3 5530- 000220 Ply Wood For General Purposes Bwr -aa 7ply, H4 8115-0000108 Box Rigid 152.5 X 101.5 X 76 Mm X 1.12 Mm, H4 8115-000540 Boxes Fibre Board Corrugated Size

Ref. Document
View Tender
#TBR: 36044701 Closed

Security Services

  • Uttar Pradesh
  • Due On: 25 Dec, 2025 (0 Days Left)

Gem Bids For H2 4020 000195 Twine Jute, G1 5315 000175 Pinscotter Split Steel 5 Mm X 45 Mm, H1b 6810 000010acid Hydrochloric Technical, H1b 5350 000008abrasives Cloth Emery Or Corundum Size O, H4 8115000542 Boxes Fibre Board Rigid Size 600x450x300

Ref. Document
View Tender
#TBR: 36040057 Closed

Security Services

  • Punjab
  • Due On: 08 Dec, 2025 (0 Days Left)

Gem Bids For Sodium Hydroxide Technical, Boxes Fibre Board Rigid Corrugated Size, Nails Steel Wire Round 125 Mm X 5.6 Mm, Pins Cotter Split Steel 5.5 Mm X 63 Mm, Cork Sheet 1.6mm Thick, Wire Steel Mild Annealed 2.00mm

Ref. Document
View Tender
#TBR: 35996402 Closed

Security Services

  • Punjab
  • Due On: 06 Dec, 2025 (0 Days Left)

Gem Bids For H1(b) 10596988 6840-000007 Napthalene Balls K1 10308306 7240-000008 Basket Ration With Lid H1(a) 10416164 8010-000272 Varnish Gold Size K6 10537119 7330-000074 U.c 45 Men Set Degchie 255 Mm H1(b) 10412598 5350-000005 Abrasives Cloth Emery Or Corundum Size O G2 10418810 9505-000058 Wire Steel Mild Annealed 5.00mm G1 10411331 5315-000208 Pins Cotter Split Steel 8.0 Mm X 80 Mm G2 10410603 9515-000034 Steel Sheet Carbon Galvanised Plain 1800 H9 10537303 5330-001907 Jointing Asb F/comp Gr 1.6mm 100x100cm H9 10308530 5330-001899 Cork Sheet Thick 3.2mm H4 10417030 8115-001096 Boxes Fibre Board Rigid Size 675x400x350 G2 10412891 9510-000030 Steel Bar Carbon Hot Rolled Round 40mm

Ref. Document
View Tender
#TBR: 35959306 Closed

Security Services

  • Maharashtra
  • Due On: 02 Dec, 2025 (0 Days Left)

Gem Bids For Corrugated Fibre Board Packing Box For 40mm L60cartg. Cases As Per Drg. No. Ccl60/sk/1220 Sheet 1/3,

Ref. Document
View Tender
#TBR: 35945233 Closed

Construction

  • Rajasthan
  • Due On: 25 Nov, 2025 (0 Days Left)

Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 Providing And Laying Cement Concrete Wearing Course M 30 Grade Including Reinforcement Complete As Per Drawing And Morth Specifications Clauses 1700 And 2702.2 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Fillling Joint Sealing Compound As Per Drawings And Morth Specifications With Coarse Sand And 6 Per Cent Bitumen By Weight Clause 2604 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced, Plain Cement Concrete Pavement, Thickness As Per Design, Over A Prepared Sub Base, With 43 Grade Cement Or Any Other Type As Per Clause 602.2.2 M30 (grade), Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Concrete Mixer Of Not Less Than 0.5 Cum Capacity And Appropriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film, Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days, Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately) Providing And Fixing Of Retro-reflectorised Cautionary, Mandatory And Informatory Sign As Per Irc:67 Made Of Encapsulated Lens Type Reflective Sheeting Vide Clause 801.3.1, Fixed Over Aluminium Sheeting, 1.5 Mm Thick Supported On Gi Pipe 50 Mm Dia Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M-15 Grade Cement Concrete 450 Mm X 450 Mm X 600 Mm, 600 Mm Below Ground Level As Per Drawings And Morth Specification Clause 801 600 Mm X 450 Mm Rectangular Tancha To Kohani Km. 0/300

38.85 Lacs
View Tender
#TBR: 35937767 Closed

Construction

  • Rajasthan
  • Due On: 25 Nov, 2025 (0 Days Left)

Excavation For Structures Earthwork In Excavation For Structures As Per Drawing And Morth Specifications Clause 304.1 Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Material And Disposal Upto A Lead Of 50 M, Dressing Of Sides And Bottom And Backfilling In Trenches With Excavated Suitable Material. Ordinary Soil Upto 3 M Depth Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 P.c.c Grade M 10 Nominal Mix 1:3:6 Providing Concrete For Plain/reinforced Concrete In Open Foundations Complete As Per Drawings And Morth Specifications Clause 1702, 1703, 2102 & 2104 R.c.c Grade M 20 Supplying, Fitting And Placing Hysd Bar Reinforcement In Foundation Complete As Per Drawings And Morth Specifications Clauses 1009,1600 And 2102 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c Grade M 20 Plain/reinforced Cement Concrete In Substructure Complete As Per Drawings And Morth Specification Clauses 1700 And 2200 For Height Upto 5 M R.c.c. Grade M 25 Supplying, Fitting And Placing Hysd Bar Reinforcement (fe 415) In Substructrue Complete As Per Drawings And Morth Specification Clauses 1009,1600 & 2202 Providing Weepholes In Brick Masonry/stone Masonry, Plain/reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(v):20(h) Towards Drawing Face Complete As Per Drawing And Morth Specification Clauses 1409, 2204.4, 2206.4 & 2706 Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Morth Specifications Clauses 1700, 2302 And 2304 R.c.c. Grade M 30 Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Complete As Per Drawing And Morth Specifications Clauses 1009,1600 And 2302 Providing And Laying Cement Concrete Wearing Course M 30 Grade Including Reinforcement Complete As Per Drawing And Morth Specifications Clauses 1700 And 2702.2 Providing And Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing And Morth Specifications Clause 2604 Providing And Laying Filter Media With Granular Crushed Aggregates As Per Specification To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Providing Over The Entire Surface Behind Abutment, Wing Wall, Return Wall To The Full Height, Compacted To Firm Condition Complete As Per Drawing And Morth Specification Clause 2204.6 & 2504.2.2 Backfilling Behind Abutment, Wing Wall And Return Wall Complete As Per Drawings & Morth Specification Clause 304.3.7 & 2204.6 Granular Material Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Stone Masonry, Including Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lift And Lead Of 1000 M As Per Morth Specification Clause 202. Rubble Stone Masonry In Cement Mortar Supply & Fixing Of Flood Gauge (water Gauge) As Per I.r.c. 67 Standard 200 Cm Long Fixed On Angle Iron Posts 50x50x6 Mm, 2.6 M. Long. Construction Of Embankment With Material Obtained From Borrow Pits Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305 Granular Sub-base With Close Graded Material (table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.e Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (as Per I.s.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[morth Specification : Clause 401]. By Mechanical Means. For Grading-ii Material Dry Lean Cement Concrete Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. Construction Of Un-reinforced , Plain Cement Concrete Pavement M30 (grade), Thickness As Per Design, Over A Prepared Sub Base, With 43/53 Grade Cement As Per Clause 602, Coarse And Fine Aggregates Conforming To Is:383, Maximum Size Of Coarse Aggregate Not Exceeding 31.5 Mm, Mixed In A In Fully Automatic Batching Plant And Transported To Site In Transit Mixer For Having Continuous Agitated Mixer, Manufactured As Per Approved Mix Design Including Pumping Of R.m.c. From Transit Mixer To Site Of Laying , With All Lead And Lift Including Cost Of Admixtures In Recommended Portion As Per Is 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer In Charge Laid With A Fixed Form Paver (laying And Fixing Of 150 Micron Thick Polythene Film And Finished In Continuous Operation Including Provision Of Contraction And Expansion, Construction Joints, Applying Debonding Strips, Primer, Sealant Near Approaches To Bridge/culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14-days Using Water Finishing To Lines And Grade As Per Drawing And Morth Specification Clause 602 Including Vaccum Dewatering Process With All Required Equipments (dowel Bars Will Be Paid Seprately). Painting Two Coats Including Primer Coat After Filling The Surface With Synthetic Enamel Paint In All Shades On New, Plastered / Concrete Surfaces As Per Drawing And Morth Specification Clause 801 Providing And Fixing Of Retro-reflectorised Cautionary, Mandatory And Informatory Sign As Per Irc:67 Made Of Encapsulated Lens Type Reflective Sheeting Vide Clause 801.3.1 Fixed Over Aluminium Sheeting, 1.5 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Firmly Fixed To The Ground By Means Of Properly Designed Foundation With M15 Grade Cement Concrete 450 Mm X 450 Mm X 600 Mm, 600 Mm Below Ground Level As Per Drawings And Morth Specification Clause 801 800 Mm X 600 Mm Rectangular Jharkheri To Gopal Para Km. 1/800

32.80 Lacs
View Tender
Download Document