Construction O F Second Floor In This Estimate Provisions For Rcc Columns Beams Lintel Slab Etc Rcc M20 Grade Fps Modular Clay Brick Walls Plastering Painting Vitrified Tiled Flooring Particle Board Partitions Provision For Lift General Health And Family Welfare Department Annual Plan Budget 2018 19 Health Services-Implementation Of Plan Scheme Of Women Children Hospital Vertical Extension Of District Early Intervention Centre Building For Ivf Laproscopic
Gem Bids For Sfrc Railing , Brick Fps Clay , Gsb , Cement Opc43 , Rcc Bollards 138mm Dia , Manhole Cover Hd20 , Bituminous Bags 25kg , Coarse Sand Zoneiii , Aggregate20mm , Aggregate10mm , Np3 Pipe 300mm , Np3 Pipe 450mm , Rcc Slab1.50x0.30x0.15mm , Rcc Slab1.50x0.30x0.10mm , Paver Block 60mm M35 , Tactile Tiles , Bitumen Emulsion
Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&p And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 50 Metres As Directed By Engineer.cement Concrete Grade M-15 And Above And Pcc Blocks Clearing And Grubbing Road Land Including Uprooting Rank Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Girth Up To 300 Mm, Removal Of Stumps Of Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To A Lead Of 50 Metres From Road Boundary Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Directed By Engineer.in Area Of Light Jungle Silt Clearance Of Drains, Channels And Canals With Lift 1.5 Mtr And Lead Up To 50 Mtr. Sludge Clearance Of Drains, Channels And Canals With Lift 1.5 Mtr And Lead Up To 50 Mtr. "providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level :1:3:6 (1 Cement : 3 Fine/ Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). " 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Reinforced Cement Concrete Work In Walls (any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Upto Two Stories Excluding Cost Of Centring, Shuttering, Finishing And Reinforcement : Including Providing /mixing Of Synthetic Fibers Compulsorily Complying With Is 16481:2022 Of 06 Mm/12 Mm Length To Be Mixed @ 0.25% By Weight Of Cement I.e. 125 Gms Per 50 Kg Cement Up To 900 Gms Per Cum Of Concrete/ Mortar. "reinforcement For R.c.c. Work At All Levels Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete." Centring And Shuttering With Plywood Or Steel Sheet Upto Two Stories Or Height Upto 7.5 Metre Above Plinth Level Including Strutting, Propping Etc. And Removal Of Form For :foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. Wrought Iron And Mild Steel Welded Work) (using Angles, Square Bars, Tees And Channel Grills, Grating Frames, Gates And Tree Guards Of Any Size And Design Etc. Including Cost Of Screens And Welding Rods Or Bolts And Nuts Complete Fixed In Position But Without The Cost Of Excavation And Concrete For Fixing Which Will Be Paid Separately. Providing And Fixing Of Reinforced Ferro-cement Drain Covers Designed For 'a' Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75mm To 150mm Anti Corrosive Bitumen Painted M.s. Plate , Rim And M.s. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc.standard Size 2100x500mm (150mm Thick) For Span 1201 To 1500mm Brick Work With Fps Bricks Of Class Designation 75 In Foundation And Plinth In:cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Cement Plastering Including T&p, Scaffolding, Material And Complete Labpour, Including Cost Of Water, Curing, Racking Of Joints Etc. With 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement : 4 Fine/ Coarse Sand) Providing And Laying Precast Reinforced Cement Concrete Box Culvert Section Of M-40 Grade Designed For 'aa' Class Loading As Per Irc Specifications Including The Effect Of Impact, Eq Etc. Complete On Firm Base Of 200mm Thick Lean Concrete Of M-10 Grade With Aggregate Of Size 40mm Nominal Of Following Internal Sizes. The Work Includes Required Safety Measures, Construction Of Drain For Diversion Of Flowing Water, Cost Of Design Of Rcc Precast Box And Its Proof Checking From Iit/mnit Jaipur Etc. Complete In All Respect As Per Specifications Diversion Of Flowing Water, Cost Of Design Of Rcc Precast Box And Its Proof Checking From Iit/mnit Jaipur Etc. Complete In All Respect As Per Specifications Size 2.00 M X 2.00 M Providing, Laying, Spreading And Compacting Of Granular Sub-base By Providing Close Graded Material, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material To Work Site, Spreading In Uniform Layers With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Mort&h Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion.grading - I Material Providing, Laying, Spreading (with Paver Finisher Only) And Compacting Wet Mix Macadam (wmm) Base Course Comprising Of Graded Stone Aggregate And Granular Material Conforming To Mort&h Specifications (table 400-ii) In Layers Of Equal Compacted Thickness Each Consolidated, Including Pre-mixing The Material With Water At Omc In Mechanical Mixer (pug Mill), Carriage Of Mixed Material By Tippers To Site, Laying In Uniform Layers In Base Course On A Well Prepared Sub-base/ Base Course And Compacting With Power Vibratory-roller To Achieve The Desired Density Complete As Per Mort&h Specification Clause - 406 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg/sqm With The Help Of Spray Set Fitted On Bitumen Container (boiler) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&h Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. Providing And Applying Tack Coat On The Prepared Surface With Bitumen Emulsion As Per Is: 8887 And Approved Quality @ 0.2 Kg/sqm With The Help Of Spray Set Fitted On Bitumen Container (boiler) After Cleaning The Surface With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&h Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. "providing And Laying 50-75 Mm Compacted Thick Design Mix (approved By Engineer) Dense Bituminous Macadam On Prepared Surface With Specified Graded Crushed Aggregates As Per Table 500-9, 500-10 With Bitumen Binder Set (including Cost Of Anti Stripping Compound Minimum 1% In Lime/cement As Per Design Wherever Required) For Base/ Binder Course Including Loading Of Material With F.e. Loader, Heating And Mixing Of Stone Aggregate, Filler And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control As Per Clause 504.3.5 To The Required Level And Grade, Compacting By Power Rollers And Vibratory Rollers Or 150 To 250 Kn Pneumatic Tyred Roller With Tp = 0.7 Mpa To Achieve The Desired Density (approximately 2.3 Tonne/cum) Complete As Per Clause 507 Of Mort&h Specification But Excluding Primer/tack Coat, Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion.grade-ii With Bitumen Vg-grade 30 @ 4.25 %, Lime Filler @ 2% (percent By Weight Of Total Mix)" "providing And Laying 30-45 Mm Compacted Thickness Bituminous Concrete As Per Design Mix (approved By Engineer) On Prepared Surface With Specified Grade Stone Aggregate As Per Table - 500-18 With Bitumen For Wearing Course Including Loading Of Aggregate With F.e. Loader And Hot Mixing Of Stone Aggregate And Bitumen (including Cost Of Anti Stripping Compound Minimum 1% In Lime/cement As Per Design Wherever Required) In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensing Device (as Per Clause 504-3.5) To The Required Level And Grade And Compacting By Power Rollers And Vibratory Rollers Or 150 To 250 Kn Pneumatic Tyred Roller With Tp = 0.7 Mpa, To Achieve The Desired Density Complete As Per Clause 509 Of Mort&h Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Primer/tack Coat.grade-ii With Bitumen Vg-grade 30 @ 6% (percent By Weight Of Total Mix)" "earth Work In Excavation In Open Area, Stp, Wtp, Pumping Station With Mechanical Means Including Dressing Of Sides And Ramming Of Bottoms, Including Getting Out The Excavated Material, Disposal Of Excavated Material Lead Upto 1000m At Suitable Site As Per As Per Drawing And As Per Direction Of Engineer. (measurements For Payment To Be Done As Per Standard Drawings). Above 3.0 M And Upto 6.0 M Depth" Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&p And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 50 Metres As Directed By Engineer. Cement Concrete Grade M-15 And Above And Pcc Blocks Clearing And Grubbing Road Land Including Uprooting Rank Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Girth Up To 300 Mm, Removal Of Stumps Of Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To A Lead Of 50 Metres From Road Boundary Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Directed By Engineer.in Area Of Light Jungle Silt Clearance Of Drains, Channels And Canals With Lift 1.5 Mtr And Lead Up To 50 Mtr. Sludge Clearance Of Drains, Channels And Canals With Lift 1.5 Mtr And Lead Up To 50 Mtr. "providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level : 1:3:6 (1 Cement : 3 Fine/ Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). " 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Brick Work With Fps Bricks Of Class Designation 75 In Foundation And Plinth In: Cement Plastering Including T&p, Scaffolding, Material And Complete Labpour, Including Cost Of Water, Curing, Racking Of Joints Etc. With 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement : 4 Fine/ Coarse Sand) Reinforced Cement Concrete Work In Walls (any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Upto Two Stories Excluding Cost Of Centring, Shuttering, Finishing And Reinforcement : Including Providing /mixing Of Synthetic Fibers Compulsorily Complying With Is 16481:2022 Of 06 Mm/12 Mm Length To Be Mixed @ 0.25% By Weight Of Cement I.e. 125 Gms Per 50 Kg Cement Up To 900 Gms Per Cum Of Concrete/ Mortar. "reinforcement For R.c.c. Work At All Levels Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete." Centring And Shuttering With Plywood Or Steel Sheet Upto Two Stories Or Height Upto 7.5 Metre Above Plinth Level Including Strutting, Propping Etc. And Removal Of Form For :foundations, Footings, Bases Of Columns, Etc. For Mass Concrete. Wrought Iron And Mild Steel Welded Work) (using Angles, Square Bars, Tees And Channel Grills, Grating Frames, Gates And Tree Guards Of Any Size And Design Etc. Including Cost Of Screens And Welding Rods Or Bolts And Nuts Complete Fixed In Position But Without The Cost Of Excavation And Concrete For Fixing Which Will Be Paid Separately. Providing And Fixing Of Reinforced Ferro-cement Drain Covers Designed For 'a' Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75mm To 150mm Anti Corrosive Bitumen Painted M.s. Plate , Rim And M.s. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc.standard Size 2100x500mm (150mm Thick) For Span 1201 To 1500mm Dismantling Of Flexible Pavements For Sewer Line And Manholes And Disposal Of Dismantled Materials Up To A Lead Of 50 Metres As Directed By Engineer Including Allowances For Any Additional Dismantling Beyond The Drawings (measurement For Payment To Be As Per Standard Drawings), Re-handling Of Material/earth To Complete The Task. Bituminous Courses Granular Courses "providing, Laying, Spreading And Compacting Of Granular Sub-base By Providing Close Graded Material, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material To Work Site, Spreading In Uniform Layers With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Mort&h Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. Grading - I Material" Providing, Laying, Spreading (with Paver Finisher Only) And Compacting Wet Mix Macadam (wmm) Base Course Comprising Of Graded Stone Aggregate And Granular Material Conforming To Mort&h Specifications (table 400-ii) In Layers Of Equal Compacted Thickness Each Consolidated, Including Pre-mixing The Material With Water At Omc In Mechanical Mixer (pug Mill), Carriage Of Mixed Material By Tippers To Site, Laying In Uniform Layers In Base Course On A Well Prepared Sub-base/ Base Course And Compacting With Power Vibratory-roller To Achieve The Desired Density Complete As Per Mort&h Specification Clause - 406 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. Providing And Applying Tack Coat On The Prepared Surface With Bitumen Emulsion As Per Is: 8887 And Approved Quality @ 0.2 Kg/sqm With The Help Of Spray Set Fitted On Bitumen Container (boiler) After Cleaning The Surface With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&h Specification Including All Material, Labour, Machinery Lighting, Guarding And Maintenance Of Diversion. Providing And Laying 50-75 Mm Compacted Thick Design Mix (approved By Engineer) Dense Bituminous Macadam On Prepared Surface With Specified Graded Crushed Aggregates As Per Table 500-9, 500-10 With Bitumen Binder Set (including Cost Of Anti Stripping Compound Minimum 1% In Lime/cement As Per Design Wherever Required) For Base/ Binder Course Including Loading Of Material With F.e. Loader, Heating And Mixing Of Stone Aggregate, Filler And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control As Per Clause 504.3.5 To The Required Level And Grade, Compacting By Power Rollers And Vibratory Rollers Or 150 To 250 Kn Pneumatic Tyred Roller With Tp = 0.7 Mpa To Achieve The Desired Density (approximately 2.3 Tonne/cum) Complete As Per Clause 507 Of Mort&h Specification But Excluding Primer/tack Coat, Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. Grade-ii With Bitumen Vg-grade 30 @ 4.25 %, Lime Filler @ 2% (percent By Weight Of Total Mix) Providing And Laying 30-45 Mm Compacted Thickness Bituminous Concrete As Per Design Mix (approved By Engineer) On Prepared Surface With Specified Grade Stone Aggregate As Per Table - 500-18 With Bitumen For Wearing Course Including Loading Of Aggregate With F.e. Loader And Hot Mixing Of Stone Aggregate And Bitumen (including Cost Of Anti Stripping Compound Minimum 1% In Lime/cement As Per Design Wherever Required) In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensing Device (as Per Clause 504-3.5) To The Required Level And Grade And Compacting By Power Rollers And Vibratory Rollers Or 150 To 250 Kn Pneumatic Tyred Roller With Tp = 0.7 Mpa, To Achieve The Desired Density Complete As Per Clause 509 Of Mort&h Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Primer/tack Coat. Grade-ii With Bitumen Vg-grade 30 @ 6% (percent By Weight Of Total Mix)
"part-a (building Work) Based On Bsr Pwd - 2019, Dausa Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Sandy Soil Free From Deleterious And Organic Material Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sandy Soil With All Lead And Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12mm (av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1white Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete.green / Blackabove 3601 Cm2 Slabs Providing And Fixing 1st Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200mm X 300mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (excluding The Cost Of Cement Plaster On Walls And Pillar). "part-b (sanitary Work) Based On Bsr Pwd - 2014, Dausa Circle P & F Kitchen & Lab. Sink Of Approved Make With C.i. Brackets Duly Painted, 40 Mm C.p. Waste Coupling, C.p. Brass Chain With Rubber Plug, 40 Mm G.i. Waste Pipe Up-to Floor Level Complete Including Cutting And Making Good The Wall & Floor :wvc Lab Sink (is:2556 Mark) Size 530 X 430 X 180 Mm " P & F Chromium Plated Swan-neck Laboratory Cock Of Approved Quality / Make:one Way P & F Ball Cock (is :1703 Mark) With Rod & P.v.c. Ball Complete :brass Wt.400 Gm,15mm. P & F Inlet Connection (angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.p. Inlet Connection 15mm.brass (is : 8931 Marked) P & F 15 Mm. Dia Connection Pipe Of Approved Quality/make :(-do-) 450mm. P & F Full-way Valve (is:778 Mark) Or Wheel Valve Of Approved Make :gun-metal 15mm Nominal Bore. P & F Stop Cock (is :8931 Mark), Superior Quality & Of Approved Make:brass 400 Gm. 15mm Nominal Bore. P & F Pvc Storage Tank Isi Marked (is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25mm Dia 1m Long G.i. Over-flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 500 (-do-) P & F G.i. Pipes (external Work) With G.i. Fittings Excluding Union (is : 1239 Mark) Including Trenching & Refilling Earth Etc.15mm Dia Nominal Bore'b' Class P & F G.i. Pipes (external Work) With G.i. Fittings Excluding Union (is : 1239 Mark) Including Trenching & Refilling Earth Etc.25mm Dia Nominal Bore 'a' Class Construction Of Soakage Well In All Types Of Soil Of Approved Drawing, Top 90 Cm .portion In 450mm Thick Masonry With Cm 1:6, 80 Mm Thick Stone Slab Covering, Jointing Of Slab In Cm 1:3 ,ralthal, Kharanja 40mm Thick M-15 Grade C.c Flooring, Earth Work Etc . Complete Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr . Inner Dia 90 Cm & 10 To 12 Mtr Deep. "part-c (electric Work) Based On Bsr Pwd 2013, Jaipur Circle Wiring Of Light Point/fan Point/exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is: 694) Of Approved Make Group-2 Light Point Short Point (up To 3 Mtr.)" Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3 Pin 5 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is: 694) Of Approved Make In Surface/reces Group - On Board S & F Follwing Sizes (dia.) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface/ Recessed Using Clamps, Fastener As Required Including Cutting The Wall , Covering Conduit With Wire Mess And Making Good The Same As Required. Group-2 25 Mm Dia "supplying And Drawi;ng Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi Marked (is:694) Of 1.1 Kv Grade And Approved Make In Existing Surface Ofr Necessed Conduit/ Casting Capping Including Making Connections Etc. As Required. Group-2 2 X 1.5 Sq. Mm" 2 X 2.5 Sq. Mm P & F 240/415 V Mcb Of Breaking Capacity Not Less Than 10 Ka (b/c/d Tripping Characteristic) Isi Marked Is 8828 (1996)/conforming To Iec 60898 In Existing Board/ Sheets Including Making Connections With Lugs, Testing Etc. As Required. Group-2 6 A To 32 A Rating P & F Recessed/ Surface Mounting Heavy Duty Horizontal Type Sheet Steel Distribution Board Phophatised/ Powder Painted Complete With 100 Amp Copper Copper Bus Bar, Shorting Link, Neutral, Earth Link And Din Bar, Conforming To Is 13032 & Is 8623 Including Making Internal Db Termination With Copper Lux, Testing Etc. As Reqd. . Group-2 Single Door(single Phase) 8 Way P & F Strip Fluorscent Tube Fitting Fabricated From (crca Sheet And Finished With Powder Coating/stove Enamelled Non Corrosive Uv Resist Ep Channel) Complete With Accessories(low Loss Copperchoke, Starter, Starter Seat)/electronic Choke With Terminal Block Duely Prewired With Copper Conducter Including Making Connection, Testing Etc. As Required(without Tube)1x36 Watts With Occb. Group-2 P & F Fluorscent Tube Rod In Existing Fixtures As Required, Minimum 3 Star Rating,36/40 Watts P & F Star Rated Double Ball Beari;ng Capacitor Start, Aluminium Body And Blade Ceiling Fan With Down Rod Upto 30 Cm With 3x1.5 Sqmm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc As Required.1200 Mm Sweep 3 Star Rated P & F Is:371 Marked 6 Amp Sufface Type Celling Rose Inculuding Making Commection Testing Etc. Grup-2 (e071400) P & F Isi Marked 6 Amp Bakelite Batten/ Angle Holder Including Making Connextion Testing Etc As Required P & F 18 Swg Ms Recessed Fan Box, Hexagonal/round Of Size 130mm Dia, Depth 75 Mm , 12mm Dia Rad Fan Hook With 100mm Length Extended On Eeach Side. Gourp-1 P & F 18 Swg Sheet Steel Boxes Duly Finisded With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes (nominal Size) On Surfacae Or In Recessed As Required. 175 Mmx 100 Mmx60 Mm
Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .
Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .
Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm) Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm)
Gem Bids For Upgradation, Provision And Laying Of Athletic Track With 400 M 8 Eight Lanepur Type Sandwich System Iaw World Athletics Wa Class Iistandard As Per Boq Attached Removal Of The Concretestructure And Complete Leveling To Ground Level As Per Thelatest Existing Standard With Consideration To Ground Level Ofadjacent Areas To Preclude Water Stagnation Earth Surfaceexcavation Which Includes Leveling Of The Highland Androcky Area Inside Around Stadium Boundary Withconsideration To Ground Level Of Adjacent Areas As Per Boqattached Earth Work In Surface Excavation In Foundationtrenches Drains As Per Plan With Dressing Of Sides Rammingof Bottoms Lift Up To One And Half M As Per Boq Attached Excavating Trenches Of Required Width For Pipe Cablessockets And Dressing Of Sides Ramming Of Bottoms Withdepth Upto One And Half M As Per Boq Attached Earthwork In Rough Excavation Banking Excavated Earth In Layersnot Exceeding 20 Cm In Depth Breaking Clods Wateringrolling Each Layer With One And Half Tone Roller As Per Boqattached Providing And Laying In Cement Concrete Ofspecified Grade Including Cost Of Centring And Shuttering Asper Boq Attached 148 1 Cement 4 Coarse Sand 8 Gradedstone Aggregate 40 Mm Nominal Size As Per Boq Attached Centring And Shuttering Including Sturting Propping Andremoval Of Firm Works For Foundations Footings And Bases Ofcolumns As Per Boq Attached Brick Work With Fps Bricks Ofclass Designation 75 In Foundation And Plinth In Cementmortar 14 1 Cement 4 Coarse Sand As Per Boq Attached 12Mm Cement Plaster Of Mix 1 4 Cement 4 Coaster Sand Asper Boq Attached 12Mm Cement Plaster Of Mix Neatcement Punning As Per Boq Attached Consolidation Ofsubgrade With Power Roller Of 8 To 12 Ton Capacity Torequired Slope Including Making Good Undulations Etc Withearth Or Quarry Spoils Etc As Per Boq Attached Supply And Bid Number Gem2025b6480978 Dated 17-09-2025 0 0 Bid Document1 33 0 0 2 2 Stacking Of Earth By Mechanical Transport Including Loadingunloading And Stacking At Site As Per Boq Attached, Construction Of Granular Sub Base By Providing Close Gradedmaterial Or As Per Latest Guideline For World Athleticspecification As Per Boq Attached, Providing Laying Oneand Half Spreading And Compacting Graded To Wet Mixmacadam Wmm Specification As Per Boq Attached, Providing And Applying Tack Coat Using Cold Bitumenemulsion Including Spraying The Bitumen With Mechanicallyoperated Spray Unit As Per Boq Attached, Providing Andapplying Tack Coat Using Cold Bitumen Emulsion Includingspraying The Bitumen With Mechanically Operated Spray Unitfitted On Bitumen As Per Boq Attached, Providing Andlaying Bituminous Macadam Using Crushed Stoneaggregates As Per Latest Guideline For World Athleticspecifications As Per Boq Attached, Providing And Layingbituminous Concrete Using Crushed Stone Aggregates Ofspecified Grading Or As Per Latest Guideline For Worldathletic Specifications As Per Boq Attached, Supply Andinstallation Of Fully Computerized Automatic And Single Keyoperation Popup Sprinkler System Specifically Designed Forsynthetic Sports Hockey Surfaces As Per Boq Attached, Supplying And Installation Of 50 H P Pumping Set Withelectronic Controller Etc Or Equivalent Making Connectionssuitable For Tw D C B Open Well The Jobs As Per Boqattached, Construction Of R C C Storage Tank Sump Well Of75000 Liters Capacity Complete Including All Excavation Andearth Work Disposal Of Surplus Soil As Per Boq Attached, Providing And Laying Of Dwc Sn8 Is 16098 Ii Pipes 300 Mmdia Pipe In Underground System For Provision In Electricalline And Sprinkler Line Sleeve Purposes And Drainage Outlet, Supply And Laying Rcc Drain Cover Of Size 600 X 600 X 60Mm With 8Mm Rods Per Rate 100Mm Cc Over The Walls Ofdrain At Proper Level For Ease Flow Of Water As Per Boqattached, Supply And Laying Rcc Drain Cover Of Size 600 X300 X 60 Mm With 8Mm Rods Per Rate 100Mm Cc Over Thewalls Of Drain At Proper Level For Ease Flow Of Water As Perboq Attached, Providing And Laying Minimum 15Cm Thickcement Concrete Slab Over The Existing Sub Base With Anominal Mix Of 115 3 1 Cement One And Half Coarse Sand 3Graded Stone As Per Boq Attached, Providing And Fixing Ator Near Ground Level Precast Cement Concrete Kerb Stones300 300 100Mm Of M 25Grade Of Of Specified Size Includingsetting In Position In Kerbs Edging Etc As Per Boq Attached, Cricket Pitch Preparation Earth Work In Excavation Bymechanical Means Hydraulic Excavator Manual Means Overareas Exceeding 30 Cm In Depth As Per Boq Attached, Supplying And Filling Of Good Earth Bought From Outsidestacking At Site At Site Upto 5Km Complete As Per Boqattached, Carriage Of Earth By Mechanical Transportincluding Loading Unloading And Stacking From 5Km Tosource Location As Per Boq Attached, Supplying And Fillingin Plinth With Sand Under Floors Including Watering Rammingconsolidating And Dressing Complete As Per Boq Attached, Carriage Of Sand By Mechanical Transport Including Loadingunloading And Stacking Upto10 Km As Per Boq Attached, Supply And Planting Selection One 1 Grass Incl Ploughingdressing Breaking Of Clods Removal Of Rubbish Dressing Andsupplying Doob Grass At 10 Cm Apart As Per Boq Attached, Extra For Manual Compaction Of Earth By Rammers Handroller In 250 Mm Layers Including Watering Etc If Requiredborrow Pit Measurement As Per Boq Attached, Surfacedressing Of The Ground Including Removing Vegetation Andinequalities Not Exceeding 15 Cm Deep And Disposal Of //Bid Details2 / 33 Rubbish Lead Up To 50 M And Lift Up To 1Point 5 M As Per Boqattached, Skill Labor For Drying Breaking Clay Soil Andmaking In Proper Shape And Size As Well As Laying Andnecessary Compaction Cum Soil Helper Technician As Perboq Attached, Synthetic Track Providing And Laying Ofsynthetic Athletics Track Sw Pur Type System With Min 14Mm Thickness Which Should Comply With Environmentalcompatibility As Per Boq Attached, High Stress Areas With Aminimum Thickness Of 20 Mm Of Finished Track Surface Asper Boq Attached, High Stress Areas With A Minimumthickness Of 25 Mm Of Finished Track Surface As Per Boqattached, Construction Of Sand Filling In Jumping Pits As Perboq Attached, Construction Of Steeplechase Pit Insidenorth D Portion As Per Iaaf Drawing And As Directed Byengineer In Charge As Per Boq Attached, Supply Of Sportstrack Field Equipment For Conducting Various Event A Polevault Box With Cover As Per Boq Attached, Take Off Boardsystem For Ljtj As Per Boq Attached, Hammer Cum Discussthrowing Ring With Cage As Per Boq Attached, Short Putthrowing Rings With Toe Board As Per Boq Attached, Aluminum Kerbing 400M Std Track As Per Boq Attached, Water Jump Hurdle For Steeple Chase Run As Per Boqattached, Conversion Circle Reducer For Dch As Per Boqattached
Supply Of Civil Items - Brick F.P.S. Non Modular Bricks Of Class Designation 7.5., Portland Pozzolana Cement Fly Ash Based, Red Sand Stone - Exposed Face Machine Cut And Table Rubbed, Factory Made Chamfered Edge Cement Concrete Paver Blocks
Civil Maintenance Works -Supplying And Filling In Plinth With Loc, Resources Skilled For Unmeasurable Wor, Resources Unskilled For Unmeasurable W, Supply Of Galvanised Wire Mesh Of Acerag, Painting And Lettering Of Sign Boards/ D, 6.1.2/Brick Work With F.P.S. Bricks Of C, 6.4.2/Brick Work With F.P.S. Bricks Of C