Taking down of s of any type size and model complete all as specified and directed. , Taking down of brackets of any type size and model complete all as specified and directed. , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws , Re fixing of LED s of any wattage outdoor type complete all as specified and directed. , Supply and fixing in LED 120 Watt 230 V AC outdoor type with high pressure die cast aluminum , S and F in LED flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in LED flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way bakelite , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor and sheathed flexible , S and F single arm bracket made of40mm dia 1.0mtrs long for security , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. , M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty 10 sqmm 4 core. , Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole etc. , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc , S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , Overload Relay (Q3) , Compression cable lugs (Q3)
Supply of Taking down of s of any type size and model complete all as specified , Taking down of brackets of any type size and model complete all as specified , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified , Re fixing of LED s of any wattage outdoor type complete all as specified and directed. , S and F in LED 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing. , S and F in LED flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in LED flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplasti having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees bends elbows , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc. , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , M and L Sand Cushioning dry in Trenches for protection of UG Cables , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable , S and L for cable in trenches or passing through pipe XLPE insulated wire armoured electric LT cable 25 sqmm 4 core. , S and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable a 10 sqmm 4 core. , ReLaying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable Heavy Duty , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
Supply of Taking down of s of any type size and model complete all as specified. , Taking down of brackets of any type size and model complete all as specified and directed. , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts , M and L in steel tubular swaged poles complete with cast iron base plate , Re fixing of LED s of any wattage outdoor type complete all as specified and directed. , Supply and fixing in LED 120 Watt 230 V AC outdoor type , Supply and fixing in LED flood 80 watt 230 V AC outdoor type with thermal management in multiple optics , Supply and fixing in LED flood 150 watt 230 V AC outdoor type with thermal management , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic aving IP 66 protection , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks GI Pipe etc. , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc. , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified , Removing excavated Materials Soils not exc. 50.00 mtr , M and L Sand Cushioning dry in Trenches for protec tion of UG Cables , M and L for fly ash bricks locally available laid dry width wise across the line of cable , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty , Supply and laying for cable in trenches or passing through pipe XLPE insulated 10 sqmm 4 core. , Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable 10 Sqmm 2 Core to 25 Sqmm 4 Core , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete , S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , Crimping Tools (Q3)
Supply of Taking down of s of any type size and model complete all as specified , Taking down of brackets of any type size and model complete all as specified , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug , M and L in steel tubular swaged poles complete with cast iron base plate, finial taper plug , Re fixing of LED s of any wattage outdoor type complete all as specified and directed. , S and F in LED 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing , Supply and fixing in LED flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in LED flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unservicable or servicable UG cable of any cross section area and connection etc. , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , Returning Filling in including Spreading, Levelling Watering and Well Ramming in Layers not exc. , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. , M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable , S and L for cable in trenches or passing through pipe, XLPE insulated 25 sqmm 4 core. , S and L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable 10 sqmm 4 core. , Re laying fixing or passing through XLPE insulated armored electric power UG cable etc. , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path, not exc. 10.00 mtr , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable. , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
Providing 20 Mtr High Mast With Led s On Yard And Ei In Steel Tubular Cover Shed With Led And Of With Led s In Grain Market Mamdot Mc Mamdot Work Code-Ee-E-Fzr-2024-23
Replacement Of High Mast And Flood s At Kaylana And Domestic Area At Af Stn
/ Maint Of , High Mast s Including Connected Electrical Works At Ge Clement Town
/ Maint Of , High Mast s Including Connected Electrical Works At Ge Clement Town
And Maintenance Of , High Mast s Including Connected Electrical Works At Ge Clement Town
Maintenance Of Electrical & Mechanical Installation At C.R Colony, Salimpur Dumraha, Sh: - Of Defective Led .