"नये भारत का नया Tender Portal"
Request a call back

Latest Tenders for wave trap

Total 31 tenders found
#TBR: 36275062 Closed

Security Services

  • Maharashtra
  • Due On: 22 Jan, 2026 (0 Days Left)

Gem Bids For Lv1 Wzt 3 Pn 74 E 90161 L 60mm Braid Plc 10 16 L 60mm , Lv1 Wzt 3 Szr20u5esz7 Plug Szr20u5esz7 , Lv1 Wzt 3 Szr16p2ng5 Plug Szr16p2ng5 , Lv1 Wzt 3 Pn 74 E 90161 4 Braid Plc 6 10 L 15800mm , Lv1 Wzt 3 Szr16u2eg5 Pos 689 Plug Szr16ueg5 , Lv1 Wzt 3 Szr20u2esz6 Pos 696 Plug Szr20u2esz6 , Lv1 Wzt 3 170 70 066sb 2 Cover In The Set , Lv1 Wzt 3 Pn 74 E 90161 5 Braid Plc30 40 L 60mm , Lv1 Wzt 3 Pn 89 C 89209 Zn 94 Zut 1 06 Hose Z Pvc P White Or Cinereous I O 36x3 0 L 90mm Pololefin Thermoshri , Lv1 Wzt 3 Pn 74 E 90161 6 Braid Plc 6 10 L 120mm , Lv1 Wzt 3 Sb 8 Joint With Nut Sb 8 Plug , Lv1 Wzt 3 170 107 047sb Plate In The Set , Lv1 Wzt 3 Szr28pk7esz9 Holder Szr28pk7esz9 , Lv1 Wzt 3 Pn 80 H 93830 L 400mm Wire M1 Er 0 5 L 400mm , Lv1 Wzt 3 Sz12 000 223 Sending Receiving Device R 173 , Lv1 Wzt 3 If2 067 012 Wave Trap Block R 173 14 , Lv1 Wzt 3 Pn 85 M 82105 2 Bolt M 6x30 8 8 A Fe Zn8c , Lv1 Wzt 3 Zs 1 Pod 72 Periscope Pod 72 , Lv1 Wzt 3 B 71 36 32z 1 Sleeve Assembly

Ref. Document
View Tender
#TBR: 36157816 Closed

Power

  • Rajasthan
  • Due On: 07 Jan, 2026 (0 Days Left)

Gem Bids For Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Three Phase Manual Isolators (ds) Preventative Maintenance (total Quantity 1 Is Equal To 19 Numbers .. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Three Phase Motorized Isolators (ds) Preventative Maintenance (total Quantity 1 Is Equal To 17 Numbe.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Assistance In Preventative Maintenance Of Three Phase 220kv Sf6 Circuit Breaker (total Quantity 1 Is Equal To 10 Numb.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Assistance In Preventative Maintenance Of 220 / 132 Kv Three Phase Mocb (total Quantity 1 Is Equal To 2 Numbers For T.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Cleaning And Tightness Of 220 Kv Switchyard Single Tension / Suspension String For Single Conductor (total Quantity 1.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Cleaning And Tightness Of 220 Kv Switchyard Double Insulator Suspension String For Single Conductor (total Quantity 1.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Overhead Connectors (t Connection), Clamp / Joints Inspection, Cleaning And Tightness Checks And Rep.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Overhead Connectors (y Connection), Clamp / Joints Inspection, Cleaning And Tightness Checks And Rep.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Line Tension Insulator Cleaning And Tightness Of Wall Bracket For Support At Tb Wall (total Quantity 1 Is Equal.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Cleaning And Tightness Of Sky Ground Wire Connections (tower Top And Ground) (total Quantity 1 Is Equal To 51 Set For.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Insulators Cleaning, Inspection And Connection Tightness Of Ct / Pt / Cvt / La / Sut / Gt Hv Bushin.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Assistance For Disconnection And Connection Of 220kv Ct / Pt / Cvt / Gt / Sut / Ut Terminals For Diagnostic Testing O.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Line Wave Trap Cleaning, Inspection And Connection Tightness (total Quantity 1 Is Equal To 7 Numbers For Two Ye.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Bus Post Insulators (vertically Mounted On Ground) Cleaning, Inspection And Connection Tightness (to.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 21 Kv Isolated Phase Bus Duct Cleaning, Inspection And Connection Tightness And Replacement Of Gasket And Sealing Etc.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, 220kv Switchyard Overhead Aac Strained All Aluminum Conductor / Jumper Replacement Up To Twenty Meter Length Piece (t.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of 220 / 132 Kv La (total Quantity 1 Is Equal To 6 Numbers For Two Years); As Per Scope Of Work And Atc , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of Single Tension / Suspension String / Wave Trap (of 220kv Switchyard) For Single Conductor (total Quant.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of Double Insulator Suspension String Set (of 220kv Switchyard) For Single Conductor (total Quantity 1 Is.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of 220kv Switchyard Bus Post Insulator (total Quantity 1 Is Equal To 2 Numbers For Two Years); As Per Sco.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of Insulator Of 220kv Switchyard Isolator (ds) / Ct / Pt / Cvt) I.e. Complete Unit Of One Phase (total Qu.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of Sky Wire (60 Meter Length Each) Of 220kv Switchyard (total Quantity 1 Is Equal To 5 Numbers For Two Ye.. , Repair, Maintenance, And Installation Of Plant Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of 245 Kv Sf6 Cb / Mocb Complete Unit Of One Phase / Pole (total Quantity 1 Is Equal To 3 Numbers For Two.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Replacement Of Overhead Aac Strained All-aluminum Conductor Of 30 Mm Diameter Replacement Up To 160 Meter Length Piec.. , Repair, Maintenance, And Installation Of Plant/ Systems/equipments (version 2) - Rr Site 1 And 2; Electrical System Or Installation, Site Visit Charges Of Four Persons From Bidders Premises To Rr Site Unit 1 And 2, For Carrying Out The Operational Em

29.00 Lacs
View Tender
#TBR: 35798237 Closed

Power

  • Uttar Pradesh
  • Due On: 19 Nov, 2025 (0 Days Left)

Gem Bids For Rigid Type Connector & Wave Trap Connector

Ref. Document
View Tender
#TBR: 35655115 Closed

Power

  • Arunachal Pradesh
  • Due On: 11 Nov, 2025 (0 Days Left)

Gem Bids For Wave Trap/ Line Trap For 132 Kv Switchyard

Ref. Document
View Tender
#TBR: 34651085 Closed

Power

  • Jammu And Kashmir
  • Due On: 01 Jul, 2025 (0 Days Left)

Gem Bids For 1 Purchase Of 01 No. Wave Trap For 420 Kv Pothead Yard Of Uri-ii Ps

Ref. Document
View Tender
#TBR: 34473551 Closed

Power

  • Rajasthan
  • Due On: 26 May, 2025 (0 Days Left)

Supply Of 420kv Wave Trap Installed At 2x660mw Csctpp, Chhabra

10.46 Lacs
View Tender
#TBR: 34449467 Closed

Electrical Products

  • Karnataka
  • Due On: 22 May, 2025 (0 Days Left)

Gem Bids For 132kV ST without TB for Single Zebra ACS 132kV ST with TB for Single Zebra ACSR 132kV ST w/o TB for Twin Zebra ACSR 132kV ST with TB for Twin Zebra ACSR 132kV SS with DC for Single Zebra ACSR 132KV SS Drop Type Twin Moose/ACSR 132kV SS with TC for Twin Zebra ACSR 132KV SS for Wave trap

Ref. Document
View Tender
#TBR: 34247802 Closed

Power Plant

  • Madhya Pradesh
  • Due On: 28 Mar, 2025 (0 Days Left)

Supply Of Wave Trap For 400kv Switchyard

Ref. Document
View Tender
#TBR: 34157102 Closed

Power Plant

  • West Bengal
  • Due On: 20 Mar, 2025 (0 Days Left)

Supply of TERMINAL Connector on LA to Suit 2 ACSR Moose C1 , TERMINAL Connector on BPI to Suit 4.5 IPS AL TUBE C5 , TERMINAL Connector Expansion Type on CB to Suit 4.5 IPS AL TUBE , TERMINAL Connector Expansion Type Horizontal Take Off on ISO to Suit 4.5 IPS AL TUBE C2 , TERMINAL Connector Horizontal Take Off on ISO to Suit 2 HTLS CONDUCTOR C2 , TERMINAL Connector Rigid Type Horizontal Take Off on ISO to Suit 4.5 IPS AL TUBE C2 , TERMINAL Connector Expansion Type On CT 3000A to Suit 4.5 IPS AL TUBE C3 , TERMINAL Connector On CT 3000A to Suit 2HTLS CONDUCTOR C3 , TERMINAL Connector on CVT to Suit 2ACSR Moose C4 , TERMINAL Connector on EMVT to Suit 2HTLS CONDUCTOR C5 , TERMINAL Connector Expansion Type On CB to Suit 4.5 IPS AL TUBE C6 , TERMINAL Connector on WAVE TRAP to Suit 2 HTLS CONDUCTOR C7 , Terminal connector on BPI to Suit 2ACSR Moose C8 , Tee Clamp to Suit 2HTLS to 2 HTLS CONDUCTOR T1 , Tee Clamp to Suit 2HTLS to 4.5 IPS AL TUBE Horizontal Take off T2 , Tee Clamp to Suit 2HTLS to 2ACSR MOOSE CONDUCTOR T3 , PG Clamp to Suit 2ACSR MOOSE to 2ACSR MOOSE CONDUCTOR T4 , T CLAMP FOR INVERTED V CONNECTOR TO SUIT 4.5 IPS AL TUBE T2

5.76 Lacs
View Tender
#TBR: 33751100 Closed

Power Plant

  • Tamil Nadu
  • Due On: 24 Jan, 2025 (0 Days Left)

Supply Of Mom And Bom Boxes For 110Kv Ab Switches And Erection Of 230Kv Wave Trap For Establishment Of New 230/110 Kv Ss At Sathumadurai Ts.No.022/2024-25 Of Se/Gcc/Salem Mm

7.90 Lacs
View Tender
Download Document