Supply of High Velocity Projector Detector With Transmitter Reciever & Microprocessor Based Control Unit With
Supply of Roof Mounted Ac Package Unitrmpu For Lhb Eog Coaches In Coach Sets Consisting Of Rmpu With R407c Refrigerant 02 Nos. & Microprocessor Control Unit 01 No. With Double Canvas Duct Spec. No. Rdso/Pe/Spec/Ac/0136, Rev-0 2009 Along With Letter No. El/7.2.2 Dt. 19.02.2019 Drg. No. Rdso/Pe/Sk/Ac/0069-2004, Rev 3, As Per Drawing/Specification: Rdso/Pe/Spec/Ac 0061-2005 Rev-1 Type 1 & Microprocessor To Rdso/Pe/Spec/Ac / 0139-2009 Rev 1 Complete With Access As Per Scope Of Supply In The Rdso Spec. Along With Modification Sheet No. Rdso/Pe/Ms/Ac/0077-2018, Rev.- 0..
Supply of Alind Make Microprocessor Based Control Unit For 150A 25Kva Suitable For Alind Make. W Arranty Period: 30 Months After The Date Of Delivery
Supply And Commissioning Of Rmpu, Control Panel And Microprocessor Control Unit For Use I N Self-Propelled Inspection Car Spic And Shall Meet The Following Requirements. 1.Lhb Type Roof Mounte D Ac Package Unit Type-Ii Suitable For R-407C Refrigerant Shall Be As Per Rdso Specification No. Rd So/Pe/Spec/Ac/0061-2005 Rev-1 And Micro-Processor Controller Unit Shall Be As Per Rdso Specification No. Rdso/Pe/ Spec/Ac/0139-2009 Rev.1, Type-I. 2.Ac Control Panel For Rmpu Shall Have Switch Gears Like Cont Actors, Mpcb, Mcb, Relays, Ovrs, Indication Lamp Etc., As Per Rcf Drg: No. Sked 625, Rdso/Pe/ Sk/Ac/01 90-2015 Rev.0, Rdso/Pe/ Sk/Ac/0186-2015 Rev.0 & Rdso/Pe/ Sk/Ac/0158- 2011 Rev.0, To The Above Specification. The Cage Clamp Type Terminal Connectors Required For Input And Output Power And Control Cables Of Rmpu Shall Be Provided In The Control Panel Acceptable Makes Of Terminal Blocks Are Wago, Phoenix, Wei Dmuller, Connectwell & Elmex. 3.The Overall Dimension Of The Control Panel Shall Not Exceed 550 Mm X 800Mm X 200Mm Wxhxd. 4.The Micro-Processor Controller And Switch Panel As Per Drg.No. Rdso/Pe/Sk/A C/0125 Rev.1 2009 Shall Be Integrated In To Ac Control Panel. 5.The Control Panel Shall Be Supplied Along With Po Wer And Control Cables For Connecting With Rmpu As Per Rcf Specn-Edts-252, Rev-I, Annexure-B Harness No S-31, 31A31b, 31C, 31D&31E To A Length Of 10Mtrs For Operation Of Rmpu. 6.The Overall Dimensional Drawing And Bom For The Control Panel Shall Be Submitted For Approval Before Offering For Prototype Inspection. Note: 1 Earth Ing Lug Arrangement On Rmpu Shall Be As Per Drg No.Icf/ Sk3-7-6-035 Ii Packing Instruction: Roof Mounted Ac Package Unit Packed With Corrugated Paper With Water Proof Jute Fabric And Supplied And St Acked In Pallets At Icf. The Pallets Should Be Painted And Have Firms Logo For Identification. The Firm Will Collect E Mpty Pallets Only After Ac Package Unit Is Loaded In The Coach. Warranty Period: 30 Months After The Date Of Del Ivery
Supply of Microprocessor Based Control Unit With Inbuilt Vaccum.
Supply of Microprocessor Based Control Unit With Inbuilt Vaccum And Hot Air Turbine Soldering/De-Soldering Rework Station As Per Specification Attached In Documents. Warranty Period: 30 Months After The Date Of Delivery
Supply And Commissioning Of Rmpu, Control Panel And Microprocessor Control Unit For Use In Self-Propelled Inspection Car Spic And Shall Meet The Following Requirements. 1.Lhb Type Roof Mounted Ac Package Unit Type-Ii Suitable For R-407C Refrigerant Shall Be As Per Rdso Specification No. Rdso/Pe/Spec/Ac/0061-2005 Rev-1 And Micro-Processor Controller Unit Shall Be As Per Rdso Specification No. Rdso/Pe/ Spec/Ac/0139-2009 Rev.1, Type-I .2.Ac Control Panel For Rmpu Shall Have Switch Gears Like Contactors, Mpcb, Mcb, Relays, Ovrs, Indication Lamp Etc., As Per Rcf Drg: No. Sked 625, Rdso/Pe/Sk/Ac/0190-2015 Rev.0, Rdso/Pe/ Sk/Ac/0186-2015 Rev.0 & Rdso/Pe/ Sk/Ac/0158- 2011 Rev.0, To The Above Specification. The Cage Clamp Type Terminal Connectors Required For Input And Output Power And Control Cables Of Rmpu Shall Be Provided In The Control Panel Acceptable Makes Of Terminal Blocks Are Wago, Phoenix, Weidmuller, Connectwell & Elmex. 3.The Overall Dimension Of The Control Panel Shall Not Exceed 550 Mm X 800Mm X 200Mm Wxhxd. 4.The Micro-Processor Controller And Switch Panel As Per Drg.No. Rdso/Pe/Sk/Ac/0125 Rev.1 2009 Shall Be Integrated In To Ac Control Panel. 5.The Control Panel Shall Be Supplied Along With Power And Control Cables For Connecting With Rmpu As Per Rcf Specn-Edts- 252, Rev-I, Annexure-B Harness Nos-31, 31A31b, 31C, 31D&31E To A Length Of 10Mtrs For Operation Of Rmpu. 6.The Overall Dimensional Drawing And Bom For The Control Panel Shall Be Submitted For Approval Before Offering For Prototype Inspection. Iearthing Lug Arrangement On Rmpu Shall Be As Per Drg.No.Icf/Sk3-7-6-035. Please Visit Icf Vendor Portal For Downloading Drawing Https://Vp.Icf.Gov.In/Vendtendordetnew.Php Using Key :08232K90zuf1845 Warranty Period: 30 Months After The Date Of Delivery
Supply And Commissioning Of Rmpu, Control Panel And Microprocessor Control Unit For Use In Self-Propelled Inspection Car Spic And Shall Meet The Following Requirements. 1.Lhb Type Roof Mounted Ac Package Unit Type-Ii Suitable For R-407C Refrigerant Shall Be As Per Rdso Specification No. Rdso/Pe/Spec/Ac/0061-2005 Rev-1 And Micro-Processor Controller Unit Shall Be As Per Rdso Specification No. Rdso/Pe/ Spec/Ac/0139-2009 Rev.1, Type-I. 2.Ac Control Panel For Rmpu Shall Have Switch Gears Like Contactors, Mpcb, Mcb, Relays, Ovrs, Indication Lamp Etc., As Per Rcf Drg: No. Sked 625, Rdso/Pe/Sk/Ac/0190-2015 Rev.0, Rdso/Pe/ Sk/Ac/0186-2015 Rev.0 & Rdso/Pe/ Sk/Ac/0158- 2011 Rev.0, To The Above Specification. The Cage Clamp Type Terminal Connectors Required For Input And Output Power And Control Cables Of Rmpu Shall Be Provided In The Control Panel Acceptable Makes Of Terminal Blocks Are Wago, Phoenix, Weidmuller, Connectwell & Elmex. 3.The Overall Dimension Of The Control Panel Shall Not Exceed 550 Mm X 800Mm X 200Mm Wxhxd. 4.The Micro-Processor Controller And Switch Panel As Per Drg.No.Rdso/Pe/Sk/Ac/0125 Rev.1 2009 Shall Be Integrated In To Ac Control Panel. 5.The Control Panel Shall Be Supplied Along With Power And Control Cables For Connecting With Rmpu As Per Rcf Specn-Edts- 252, Rev-I, Annexure-B Harness Nos-31, 31A31b, 31C, 31D&31E To A Length Of 10Mtrs For Operation Of Rmpu. 6.The Overall Dimensional Drawing And Bom For The Control Panel Shall Be Submitted For Approval Before Offering For Prototype Inspection. Note: Iearthing Lug Arrangement On Rmpu Shall Be As Per Drg.No.Icf/Sk3-7-6-035. Please Visit Icf Vendor Portal For Downloading Drawing Https://Vp.Icf.Gov.In/Vendtendordetnew.Php Using Key :0823Gsegwzw1203 Warranty Period: 30 Months After The Date Of Delivery
Supply of Roof Mounted Package Unit Complete Including Resilient Mounting, Flexible Duct Bellow, Connectors Complete With Plugs And Accessories As Per Clause No 2.2 Rdso Specification Rdso Specno.Rdso/Pe/Spec/Ac/0061-2005 Rev-1 For Type - I Suitable To Lhb Ac Coaches Except Generator Car With Out Microprocessor Control Unit.
Supply of 10 Microprocessor Based Control Unit Programmed Logical Controller To Sidwal Part No Sr8plc Q3 Emergency Inverter With Control Unit To Sidwal Part No Wbr8703036077 Q3